HARGROVE GAS LOGS

 

ROBERT SHAW 7000MV(RME-PO)              

MILLIVOLT GAS VALVE SYSTEM  

INSTALLATION INSTRUCTIONS

 

 

 

This  gas  pilot  safety  valve  provides  100%  shut-off  of 
both  pilot  and  main  burner  gas  supply  in  the  event  of 
pilot  flame  failure.    This  valve  is  equipped  with  a 
manual  gas  control  knob  to  provide  for  pilot  lighting.  
It also has a control knob that controls flame height. 
 
If the pilot flame goes out during normal operation, or 
if  there  is  insufficient  pilot  flame  to  provide  proper 
thermocouple  output,  the  safety  valve  will  close, 
stopping the flow of all gas.  This valve is designed for 
use on all domestic heating gases up to 1/2" PSI. 

 

CAUTIONS

 

 

1.  This  valve  should  be  installed  only  by  an 
experienced  service  technician trained in gas 
safety equipment. 
2. Turn off gas supply before installing valve. 
3. All piping must meet applicable local codes 
and ordinances and the national fuel gas code 
(ANSI Z223.1/NFPA  NO. 54) 
4.  All  wiring  must  meet  applicable  electrical 
codes and ordinances. 
5.  Check  out  the  complete  system  after 
installing the valve. 
6.  Prior  to  installation,  verify  conformance 
with  burner  manufacturer's  installation 
instructions. 

7. Make sure all piping is free of foreign matter.

 

FOR YOUR SAFETY

 

 
IF YOU SMELL GAS:

 

 
1. OPEN WINDOWS 
 
2. DON'T TOUCH ELECTRICAL 
SWITCHES 
 
3. EXTINGUISH ALL OPEN FLAMES 
 
4. IMMEDIATELY CALL YOUR GAS  
SUPPLIER

 

 

FLAMMABLE  VAPORS  MAY  BE 
DRAWN BY AIR CURRENTS FROM 
OTHER  AREAS  OF  YOUR  HOUSE 
TO THIS APPLIANCE.

 

FOR YOUR SAFETY

 

 

DO 

NOT 

STORE 

OR 

USE 

GASOLINE OR  
OTHER 

FLAMMABLE 

VAPORS 

AND LIQUIDS IN THE VICINITY OF 
THIS OR ANY OTHER APPLIANCE. 

Summary of Contents for RME-PO

Page 1: ...by an experienced service technician trained in gas safety equipment 2 Turn off gas supply before installing valve 3 All piping must meet applicable local codes and ordinances and the national fuel gas code ANSI Z223 1 NFPA NO 54 4 All wiring must meet applicable electrical codes and ordinances 5 Check out the complete system after installing the valve 6 Prior to installation verify conformance wi...

Page 2: ...rom gas supply to valve and from valve to burner must be supplied by installer when installed outside the firebox Remote Control optional ordered separately A RC A12V J 12 Volt battery operated remote and receiver B RC 110 V requires 110 Volt electricity for the receiver Note Piping from gas supply to valve and from valve to burner must be supplied by installer when installed outside the firebox P...

Page 3: ...rmostat wire 18 gauge wire from the electrical box to the millivolt valve At the valve connect the lead wires to the two outside terminals labeled TH On the switch connect a lead wire to each terminal Fig 4 2 Mount the wall switch to the electrical box and install cover plate If installing a remote control attach the leads from the receiver to the same terminals as the wall switch on the MV C 69 6...

Page 4: ...2 Screws RSTPG 48 WIRING SCHEMATIC SWITCHING DEVICES WALL SWITCH REMOTE CONTROL BARK CHIP SWITCH AND PINECONE SWITCH PILOT GENERATOR RSMVNG C VALVE GAS CONTROL KNOB WALL SWITCH use installation instructions accompanying any other switching device 1 To install a wall switch mount a standard 3 X 2 electrical box in the wall near the fireplace Run thermostat wire 18 gauge wire from the electrical box...

Page 5: ...CEDURE CAUTION Make sure the wall switch and remote are in the off position before lighting the pilot 1 Turn the gas control knob to the off position it will be necessary to depress the knob slightly at the pilot position Allow five minutes for any gas in the combustion chamber to escape LP gas which is heavier than air may require forced ventilation 2 Turn the gas control knob to the pilot positi...