INSTALLING

HARGROVE

GAS LOGS

PARTS LIST

1. Pedestal Grate
2. See Thru Burner (Narrow)
3. Vermiculite  (LP Gas only)
4. Fire Embers
5. Aluminum Connector
6. Concentric Pilot Control
7. Pilot Burner (LP Gas Only)
8. Regulator (LP Gas Only)
9. Volcanic Cinders
10. Damper Stop
11. Air Mixer (LP Gas Only)
12. Fire Logs (Not Shown)
13. Burner to Grate Bracket
14. Heat Shield for CPC Valve

15.

Heat Shield for Regulator

STGN-16 5/8

STBN-14

VM
EM

AC-18

CPC

RSTPBLP-18

REG-10.0

VC
DS

AM-46

SBN-GBB

HS-CPC

HS-REG

1

2

3

4

5

6

7

8

9

10

11

13

14

15

f i r e - p a r t s . c o m

Summary of Contents for CLBN 5-18

Page 1: ...n the gas log set must be burned only in a fully vented non combustible fireplace with the damper completely open and the chimney free of any obstruction or restrictions The fireplace must be designed and approved to burn wood The realistic yellow flame produces soot and carbon monoxide Under normal conditions the bi products will exhaust up the chimney If fumes or soot are evident in the room whe...

Page 2: ...creen must be in place when the appliance is operating unless other provisions for an air supply are provided The screen shall have openings for the introduction of fresh air for the unit 8 When glass fireplace doors are used always operate the gas log appliance with the doors fully open to allow fresh air for the appliance and to keep the controls from overheating 9 The minimum inlet supply press...

Page 3: ...for installation in vented fireplaces The minimum size of chimney flue is 8 inches in diameter Appliance Input Rate Natural Gas 56 000 Btu hr Propane 46 000 Btu hr Front Width Rear Width Depth TABLE I Minimum Minimum Front Minimum Minimum Set Size Rear Width Opening Width Depth Height 18 26 26 22 22 21 26 26 22 22 FIREPLACE SIZES FACTORY BUILT FIREPLACES MASONRY FIREPLACES Fireplace Height Minimum...

Page 4: ... Control 7 Pilot Burner LP Gas Only 8 Regulator LP Gas Only 9 Volcanic Cinders 10 Damper Stop 11 Air Mixer LP Gas Only 12 Fire Logs Not Shown 13 Burner to Grate Bracket 14 Heat Shield for CPC Valve 15 Heat Shield for Regulator STGN 16 5 8 STBN 14 VM EM AC 18 CPC RSTPBLP 18 REG 10 0 VC DS AM 46 SBN GBB HS CPC HS REG 1 2 3 4 5 6 7 8 9 10 11 13 14 15 fire parts com ...

Page 5: ...e and burner for reference points Remove the grate and proceed with the gas connection See Figure 2 GAS CONNECTION 1 The gas supply line should be Inside Diameter ID up to 30 feet and for longer distance 2 Use the aluminum connector to connect gas supply to the regulator on the STBN assembly When bending aluminum tubing use proper bending procedures to avoid kinking the tube Do not use corrugated ...

Page 6: ...ected toward the thermocouple GRATE PLACEMENT Place the pedestal grate over the burner with one of the legs inside the SBN GBB burner to grate position bracket The ember burner pan will now be positively positioned in relation to the grate LOG PLACEMENT The longest logs are front logs They should be placed on the front angled portion of the grate with the flat sides facing inward and toward each o...

Page 7: ...ter Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and or gas control which has been underwater E Keep the appliance area clear and free from combustible materials gasoline and other flammable liquids LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clock...

Page 8: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...

Reviews: