Parts list

ITEM DESCRIPTION

1.  Pedestal Grate
2.  Ember Burner
3.  HVF-Burner
4.  Burner Brackets 
5.  Embers
6.  Burner Connector
7.  Sand
8.  Volcanic Cinder
9.  Fire Logs
10.Damper Stop
11.  Aluminum 
       Connector
12. HVF-Orifice
13. EB Orifice
      EB Orifice Insert
14. 3/8 FL x 1/2 Elbow
      (2 Required)
15.  Regulator
16.  Standard Orifice
18.  Super Wool 

21” SETS

PG-16

EB-14

HBF-18

PGRG2124

EM-1

RGAC-19

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#39

HCPP-4#23

Swedge-4

50-6-8

REG-4.0

46-6-8

NOT SHOWN

24” SETS

PG-20

EB-18

HBF-24

PGRG2124

EM-1

RGAC-17

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#30

HCPP-4#23

Swedge-4

50-6-8

REG-4.0

46-6-8

NOT SHOWN

30” SETS

PG-25
EB-22

HBF-24

PGRG30

EM-1

RGAC-16

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#30

HCPP-4#22

Swedge-4

50-6-8

REG-4.0

46-6-8

NOT SHOWN

1

3

2

6

7

5

8

9

11

12

13

15

14

16

4.

10.

FIRE LOGS 
NOT SHOWN

f i r e - p a r t s . c o m

Summary of Contents for AKRG5/8NG

Page 1: ...r flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 5 If you cannot reach your gas supplier call the fire department ...

Page 2: ...as is burning and the damper is open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A fireplace screen must be in place when the appliance is operating unless other provisions for an air supply are provided The screen shall have openings for the introduction of fresh air for the unit 8 Wh...

Page 3: ...E II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input Rate kBTU hr 20 30 40 50 60 70 80 90 100 110 120 6 8 10 15 20 30 Chimney Height ft 17 6 25 7 33 8 41 7 49 2 56 6 64 0 71 4 78 8 86 2 93 5 16 5 23 7 31 2 38 7 45 5 52 4 59 7 66 9 74 1 81 3 88 6 15 1 21 7 28...

Page 4: ...ard Orifice 18 Super Wool 21 SETS PG 16 EB 14 HBF 18 PGRG2124 EM 1 RGAC 19 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 39 HCPP 4 23 Swedge 4 50 6 8 REG 4 0 46 6 8 NOT SHOWN 24 SETS PG 20 EB 18 HBF 24 PGRG2124 EM 1 RGAC 17 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 30 HCPP 4 23 Swedge 4 50 6 8 REG 4 0 46 6 8 NOT SHOWN 30 SETS PG 25 EB 22 HBF 24 PGRG30 EM 1 RGAC 16 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 30 HCPP 4 22 Swe...

Page 5: ...ve the grate and proceed with the gas connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supply to the manifold regulator When bending the aluminum tubing use proper bending procedures to avoid kinking the tube 3 Use the RGAC Burner Connector to connect the...

Page 6: ...ttom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of the PGRG brackets The notches should extend over the pedestal of the grate The position of the back log may be adjusted on an angle for optimal glow See Figure VI 3 The remaining logs are top logs These logs are bridged between the front logs and...

Page 7: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...