HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 55
8-7
Honeywell Aqua Stat Replacement Instructions (continued)
Step #
Operation Description
Visual Aids/Comments
11
Pull thermostat wires through wiring hole. Place
terminals on studs in terminal block and tighten in place.
Using a flat head screwdriver or other suitable object lift
the locking tabs on the wire clamp then push the wire
clamp into the wiring hole. Using a flat head
screwdriver tighten the two clamp screws.
12
Verify the thermostat temperature setting is correct.
The correct value is written on the front cover. The dial
can be adjusted using a flat head screwdriver.
13
Replace the cover and tighten the cover screw.
14
Reconnect power to furnace. If the water level was
lowered to install a new well fitting,
MAKE SURE THE
FURNACE IS FILLED WITH WATER TO THE
CORRECT LEVEL BEFORE OPERATING
HEATER.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.