HARDY MANUFACTURING CO., INC (MODEL KBP270) PAGE 11
2-6 Installation of Smoke Stacks and Condenser Stack
The space between the smoke stack opening and outside cover will need a bead of
silicone applied to fill any openings. The silicone is applied to prevent any water from
entering the outside cover. The condenser tank will also need to be sealed in this
manner. The application of silicon to these openings is illustrated by the diagram
below.
After the silicone is applied, you can install the two three foot sections of smoke stack.
The trim collar should be slid down the smoke stack until it rests on the outside cover.
The condenser stack must also be installed in the condenser stack opening. The trim
collar should be slid down the condenser stack until it rests on the outside cover.
DO NOT SEAL THE CONDENSER STACK TO THE WATER TANK
CONDENSER STACK OPENING. THIS IS THE WATER TANK VENT.
F
Water
Condenser Stack And
Collar
Do not seal Condenser
Stack to the Water Tank
Condenser Stack Opening.
Seal perimeter of Condenser
Stack Ring to Heater Hull using
Silicone Sealant.
6x8 Smoke Stack Cap
6x8 Smoke Stack
Extension.
6x8 Smoke Stack & Collar
Seal perimeter of Smoke Stack
to Heater Hull using