FIG. 4-9 CONNECTOR PINS FOR ANALOG INPUT PWA
Grounding the
Remote Pin to read
the Remote Set
Point Input
•
Momentary Reading of the Analog Input Signal.
•
The installer must put a contact or switch between the ground
and remote positions on the remote functions connector J2. The
switch must momentarily close when you want to read the input
level grounding the remote pin. This automatically sets the Rate
Set Point.
•
Continuous Reading of the Analog Input Signal.
•
In the Remote Functions connector, Install a jumper wire
between the ground and the remote. (See Fig. 4-10)