3.12
3 - Description
The following graphs show the air flow supplied by the fan and its power consumption. This result can be obtained
using two possible blade positions, namely the 3rd and the 4th. See “Adjusting the fan”
Blades in position 3:
Flow
These results have been calculated when the fan is in top gear
(high). To work out the results in first gear, decrease the values
by 15%.
Air flow and power consumption
"pos. 3" 1/4,5 (larga/high)
20000
25000
30000
35000
40000
45000
400 420 440 460 480 500 520 540
R.P.M.
m3 / h
75F
75SF
82SF
"pos. 3" 1/4,5 (larga/high)
5
10
15
20
25
400
420
440
460
480
500
520
540
R.P.M.
KW
A750
AG750
AG820
Blades in position 3:
Power consumption
These results have been calculated when the fan is in top
gear. To work out the results in first gear, decrease the values
by 45%.
Blades in position 4:
Flow
These results have been calculated when the fan is in top gear
(high). To work out the results in first gear, decrease the values
by 15%.
"pos. 4" 1/4,5 (larga/high)
25000
30000
35000
40000
45000
50000
400 420 440 460 480 500 520 540
R.P.M.
m3 / h
75F
75SF
82SF
Blades in position 4:
Power consumption
These results have been calculated when the fan is in top gear. To
work out the results in first gear, decrease the values by 45%.
"pos. 4" 1/4,5 (larga/high)
5
10
15
20
25
30
400
420
440
460
480
500
520
540
R.P.M.
KW
75F
75SF
82SF
A750
AG750
AG820
A750
AG750
AG820
A750
AG750
AG820
A750
AG750
AG820