9

SUPPLEMENT TO NAV. 550M, 800M, 1000M CENTRIFUGAL OPERATOR'S MANUAL

4.B Adjustment of Constant Pressure

Note:

 Adjust the constant boom section pressure one section at a time 

as follows: (Start with the valve turned closed before adjusting).

1. Shut-off the fi rst boom section valve switch 

(G)

.

2. Turn the adjusting screw 

(1)

 until the control unit pressure

 gauge 

(4)

 again shows the same pressure as set in step 6

  (Section 4.A). (Turn the screw clockwise for higher pressure, coun-

terclockwise for lower pressure).

3. Turn the boom section valve switch 

(G)

 back on.

4. Repeat steps 1 through 3 for the remaining boom section valves.

 

Note:

  Hereafter adjustment of the constant boom pressure will only  

 

be needed if you change to nozzles with other capacities, but  

 

not required if only changing pressure or application rate using  

 

the same nozzles.

5. Operating the control unit while driving: In order to shut off the entire 

boom, turn ON/OFF switch 

(C)

 to "Off" position. This returns all the 

pump outputs to the tank through the return system. The diaphragm 
antidrip valves ensures instantaneous closing of all noz zles.

In order to shut off one or more sections of the boom, switch one or 
more unneeded boom section valves 

(G)

 to "Off" position. The constant 

pressure device ensures that the pressure does not increase in the 
sections which are still operating.

In case of electrical failure, it is still possible to manually override all 
functions of the operating unit. To operate manually, disconnect the 
multiplug from the spraybox fi rst and operate the handles by hand. It is 
possible to change pressure, turn boom sections on or off, or shut off 
the complete control unit manually.

IMPORTANT:

 When the sprayer is stored, the spraybox and the 

multiplug must be protected against moisture and dirt. A plastic 
bag may be used to protect the multiplug. Store the control box in 
a clean dry place.

Summary of Contents for Navigator 550M Centrifugal

Page 1: ...Supplement to NAVIGATOR 550M 800M 1000M Centrifugal Operator s Manual 67801403 8 10 ...

Page 2: ......

Page 3: ...n design material or specification without notice thereof HARDI and other product names are registered trademarks of HARDI Inc in the U S and in other countries 67801403 8 10 Supplement to NAVIGATOR 550M 800M 1000M Centrifugal Operator s Manual ...

Page 4: ......

Page 5: ...tion information Some of the features on your HARDI sprayer were suggested by growers There is no substitute for on farm experience and we invite your comments and suggestions If any portion of this instruction book remains unclear after reading it contact your HARDI dealer or service personnel for further explanation before using the equipment For Product Service or Warranty Information Please co...

Page 6: ...perating instructions for models equipped with the Spraybox II control box and 39 pin wiring The updated two year Warranty Policy has also been included The section numbers in this supplement correspond to the section numbers in the Operator s Manual where this information would be found For example section 3 A in this supplement is the first supplement A to section 3 in the Operator s Manual Any f...

Page 7: ...ansducer 7 Speed transducer Power supply Power requirement is 12V DC Note polarity The wires must be at least 10 awg 4 0 mm2 to ensure a sufficient power supply For the operat ing unit the tractor circuit should have an 8 Amp fuse The supplied power connector is standard on most newer tractors If using a tractor with a different power connector it is necessary to disassemble con nector and attach t...

Page 8: ... Installation of control unit brackets The supplied tractor pillar bracket A has a hole spacing of 3 9 in 100mm and 4 7 in 120mm Check tractor instructions manual for information regarding attachment points Three tubes B are supplied One two or all three may be used They can be bent and shortened A spacer C is also supplied to allow further attachment possibilities Find the best solution for your ...

Page 9: ...the socket When disconnecting the plug the metallic tab must be pushed back before the plug is pulled out Speed transducer for tractor sprayer Note the following if the speed transducer is fitted to the tractor The speed transducer is an inductive type It requires a metallic protru sion e g bolt head to pass by it to trigger a signal Recommended dis tance between protrusion and transducer is 1 8 to...

Page 10: ... sure that all the nozzles are the same type and capacity 2 With the tractor in neutral engage the tractor hydraulic lever or P T O to start the pump Adjust the R P M s until the number of revolutions corresponds to the intended traveling speed 3 Open or close Agitation knob located at the top of the Manifold Control Panel depending on whether pressure agitation is required Remember pressure agita...

Page 11: ...erating the control unit while driving In order to shut off the entire boom turn ON OFF switch C to Off position This returns all the pump outputs to the tank through the return system The diaphragm antidrip valves ensures instantaneous closing of all nozzles In order to shut off one or more sections of the boom switch one or more unneeded boom section valves G to Off position The constant pressur...

Page 12: ...amages resulting from delay or any consequential damage 2 We cannot be held responsible for loss of livestock loss of crops loss because of delays in harvesting or any other expense or loss incurred for labor supplies substitute machinery rental for any other reason or for injuries either to the owner or to a third party nor can we be called upon to be responsible for labor charges other than orig...

Page 13: ... the pump being inspected and approved for replacement or repair by HARDI personnel before HARDI will accept any liability hereunder 10 HARDI reserves the right to incorporate any change in design in its products without obligation to make such changes on units previously manufactured 11 The judgement of the HARDI Service Department in all cases of claims under this warranty shall be final and conc...

Page 14: ......

Page 15: ......

Page 16: ...1A6 Phone 519 659 2771 Fax 519 659 2821 For Product Service or Warranty Information Please contact your local HARDI dealer To contact HARDI directly Please use the HARDI Customer Service number 1 866 770 7063 Or send your email to CUSTSERV hardi us com HARDI NORTH AMERICA INC Visit us online at www hardi us com ...

Reviews: