INSTALLATION INSTRUCTIONS CONT.
Under all circumstances, make sure the Ceramic Cooktop is well ventilated and the air inlet and outlet is not
blocked. Ensure the Ceramic Cooktop is in good working state (as shown below).
NOTE:
Ensure that there is a minimum 760mm between the cooktop and an overhanging surface or rangehood.
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
760
50 minimum
20 minimum
Air intake
Air ventilation 5mm
WARNING: ENSURING ADEQUATE VENTILATION
Make sure the Ceramic Cooktop is well ventilated and that air inlet and outlet is not blocked. In order to
avoid accidental touch with the overheating bottom of the cooktop, or getting unexpected electric shock
during working, it is necessary to put a wooden insert, fixed by screws, at a minimum distance of 50mm
from the bottom of the cooktop. Follow the requirements below.
IMPORTANT:
• There are ventilation holes around outside of the cooktop. You must ensure these holes are not blocked
by the worktop when you put the cooktop into position.
• Be aware that the glue that join the plastic or wooden material to the furniture, has to resist to
temperature not below 150 °C, to avoid the unstuck of the paneling.
• The rear wall, adjacent and surrounding surfaces must therefore be able to withstand an temperature
of 90 °C.
760mm
Min. 30mm
Wall