Page 8

Care and Troubleshooting of your HID Lights

CAuTION:

 HID lamps emit ultraviolet, visible, and infrared radiation.  HID bulbs operate at very 

high temperatures and pressures.  Possible skin or eye irritation can result from exposures exceed-
ing 15 minutes.  Do not stare at exposed lamp in operation.  During operation, the bulb should be 
enclosed in a housing to prevent injury.  Do not remove bulb from equipment until it has cooled 
completely.  Never handle the bulb when it is operating or until it has cooled!

The lens of the lamps must be kept clean.  The Fog Lights should be handled with care, 
giving special attention to the quartz arc tube.  

Maintain proper electrical wiring polarity to prevent damage to the lamp.

Protect the quartz arc tube when handling the lamp.  Keep the arc lamp clean.  Do not touch 
the quartz tube or the inside surface of the reflector.  If tube or reflector are dirty, clean with 
rubbing alcohol.  Allow to dry completely before lighting.

The bulb and ballast are sensitive to external operating temperature.  Do not expose to 
extremely high or low ambient temperature.

Periodically clean the lamp by wiping with a lint free towel or swab immersed in denatured 
alcohol.  Allow to dry completely before lighting.

While HID bulbs last considerably longer than halogen bulbs, several characteristics indicate 
that a bulb is approaching the end of its life-span.  Initial symptoms of end-of-life include 
low light output and/or intermittent starting.  Visual signs include blackening at the ends of 
the arc tube and electrode tip deterioration.  Note that HID bulbs contain metals, including 
mercury, that can be harmful to the environment.  Please dispose of any HID bulb in ac-
cordance with local, state, and federal regulations.

All lamps have a limited lifespan.  However, if you are experiencing problems with your HID 
light inspect the following: 

bulbs:

Inspect for broken arc tube or outer lamp jacket
Make a visual inspection of the bulb for broken or loose components in lamp envelope
Inspect for arc tube end blackening
Inspect for deposits inside the outer glass envelope

ballast and Capacitor points-of-failure:

 Attempt ignition a second time after properly resetting the ballast by disconnecting, wait-
ing 15 seconds, and then reconnecting the connectors attached to the lid.
Are you using identical replacement lamps? Your ballast will not work with incorrect watt-
age lamps.
Avoid possible overheat due to ambient temperature
Inspect for miswiring/pinched wires
Inspect ballast housing and wiring for mechanical damage

1.

2.

3.

4.

5.

6.

7.

8.




9.



           

Summary of Contents for 95058

Page 1: ...t our website at http www harborfreight com To prevent serious injury read and understand all warnings and instructions before use Copyright 2007 by Harbor Freight Tools All rights reserved No portion...

Page 2: ...es and automotive accessories may create sparks which may ignite the dust or fumes Keep bystanders children and visitors away from the installation area Distractions can cause you to lose control Prot...

Page 3: ...of fan blades belts pulleys and other moving parts of the engine that may cause injury or damage to the Fog Lights Do not allow the Black and Red battery cables or terminals to touch Failure to adher...

Page 4: ...en lights More light output An HID light source produces light at approximately three to five times halogen s efficiency Efficiency is measured in lumens per watt a measure of the amount of light prod...

Page 5: ...iring Harness 1 Set of Cable Ties 1 Installation Hardware 1 Switch 2 Mounting Plates 2 Adhesive Mounting Pads NOTE The bulb is the only replacement part offered Call 1 800 444 3353 to order it Bulb Re...

Page 6: ...from fuse to the positive red battery cable Connect another wire from the fuse to the positive terminal on the switch Carefully route two more wires from the other positive terminal on the switch to...

Page 7: ...perly After use switch off the Power Switch 1 2 3 Dual Light Installation Diagram Ground Ground Ground Switch 5A Fuse Connect to positive battery terminal Fog Light Connectors Fog Light Connectors Bal...

Page 8: ...owel or swab immersed in denatured alcohol Allow to dry completely before lighting While HID bulbs last considerably longer than halogen bulbs several characteristics indicate that a bulb is approachi...

Reviews: