background image

CLOSEMOUNT-STYLE FAN MOUNTING

10

Lowes.com/harborbreeze

Temporarily hang fan on the tab on the mounting 
bracket (C) using one of the 

non-slotted

 holes in 

the canopy (B).

4. 

3. 

D

3

B

D

Remove every other motor screw (J) and motor 
washer (R)  from top of motor housing (D).

Tab

C

4

 2. 

B

Pull wires up through hole in the middle of the 
canopy (B) and attach canopy (B) to motor 
housing (D) using the three motor screws (J) and 
motor washers (R) previously removed.

J

R

2

D

B

D

J

R

Summary of Contents for WAVEPORT STYLE E-WK52NWZ5C1

Page 1: ...Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday 1 Lowes c...

Page 2: ...tand this entire manual before attempting to assemble install or operate the product Do not discard fan carton or foam inserts Should this fan need to be returned to the factory for repairs it must be...

Page 3: ...full range dimmer switch To reduce the risk of fire electrical shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects...

Page 4: ...ng 1 E Yoke Cover 1 F Light Kit Fitter 1 G Blade 5 H Blade Arm 5 I Glass Shade 1 J Motor Screw 10 preassembled K Canopy Mounting Screw 4 preassembled DESCRIPTION PART QUANTITY DESCRIPTION PART QUANTIT...

Page 5: ...ired for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring Ha...

Page 6: ...r For taller ceilings you may want to use a longer downrod not included Angle style mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blad...

Page 7: ...nt make sure open end of mounting bracket C is installed facing the higher point of the ceiling and ensure the ceiling angle is not steeper than 19 4b 5 Remove motor screws J and motor washers R from...

Page 8: ...owing manner Take the lead wires and make sure you have pulled them all the way through the top of the downrod Start at the TOP of the hanging ball on the downrod and measure 8 in of lead wire and the...

Page 9: ...CLOSEMOUNT STYLE FAN MOUNTING 1 C Slot Tab 6 A Canopy Cover B 1 B If you cut back the lead wires in Step 4 strip 1 2 in of insulation from end of of each wire white black green and blue if applicable...

Page 10: ...f the non slotted holes in the canopy B 4 3 D 3 B D Remove every other motor screw J and motor washer R from top of motor housing D Tab C 4 2 B Pull wires up through hole in the middle of the canopy B...

Page 11: ...s are different colors than referred to in the following steps stop immediately A professional electrician is recommended to determine wiring Choose wiring diagram Fig 1a Fig 1b or Fig 1c that fits yo...

Page 12: ...ors CC into outlet box 2 CC E3 Wire Connector x 4 Hardware Used CC CC 2 CC 1b FAN CONTROLLED BY PULL CHAIN LIGHT BY WALL SWITCH Connect BLACK wire from fan to BLACK wire from ceiling Connect BLUE wire...

Page 13: ...the flat side of the blade G facing up note label indicating THIS SIDE UP Align pegs on blade arm H with blade screws AA securing blade arm H to blade G by tightening blade screws AA starting with th...

Page 14: ...assembled hex nut O and lock washer P from threaded rod at top of light kit fitter F Punch center cap N out of switch housing T with a screwdriver not included Gently feed molex wires one at a time fr...

Page 15: ...de I up to light kit fitter F securing with light kit fitter screws S CAUTION Do NOT use screwdriver or power tools to tighten light kit fitter screws S Glass WILL break HAND TIGHTEN ONLY Note Do NOT...

Page 16: ...lors on the female plug for correct fit Make sure plugs are connected completely Align holes in switch housing T with holes in switch housing plate Re insert switch housing plate screws U just removed...

Page 17: ...an OFF 1 2 Use the fan reverse switch on the switch housing T to optimize your fan for seasonal performance A ceiling fan will allow you to raise your thermostat setting in summer and lower your therm...

Page 18: ...result in upward airflow that can help move stagnant hot air off the ceiling area At least twice each year lower canopy B to check downrod A assembly and then tighten all screws on fan Clean motor ho...

Page 19: ...sive wobbling 1 Blades are loose 2 Blade arms incorrectly attached 3 Unbalanced blades 4 Fan not securely mounted 5 Fan too close to vaulted ceiling 6 Set screw s on motor housing yoke is are not tigh...

Page 20: ...esponsibility The distributor assumes no responsibility whatsoever for fan installation during the limited lifetime warranty Any service performed by an unauthorized person will render the warranty in...

Page 21: ...hina REPLACEMENT PARTS LIST For replacement parts call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday Harbor Breeze is a registered trademark...

Page 22: ...roblemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6 p m y los viernes de 8 a m a 5 p m hora est n...

Page 23: ...na protecci n adecuada contra da os que puedan agravar la causa inicial de la devoluci n Aseg rese de que todas las conexiones el ctricas cumplan con los c digos y ordenanzas locales el C digo El ctri...

Page 24: ...r con un regulador de intensidad de rango completo Para reducir el riesgo de incendio descarga el ctrica o lesiones personales no doble los brazos de las aspas al instalarlos al equilibrar las aspas o...

Page 25: ...minaci n 1 G Aspa 5 H Brazo del aspa 5 I Pantalla de vidrio 1 J Tornillo del motor 10 preensamblado K Tornillo de montaje de la base 4 preensamblado DESCRIPCI N PIEZA CANTIDAD DESCRIPCI N PIEZA CANTID...

Page 26: ...n Cinta aislante destornillador Phillips pinzas gafas de seguridad escalera de tijera y pinzas pelacables Herramientas tiles no se incluyen Luz de prueba CA cinta m trica manual de cableado H galo ust...

Page 27: ...mienda utilizar una varilla m s larga no incluida El montaje en ngulo es el mejor para los techos en ngulo o de b veda En ocasiones es necesaria una varilla m s larga para asegurar una adecuada separa...

Page 28: ...ci n hacia el punto m s alto del techo y aseg rese de que el ngulo del techo no sea superior a 19 4b 5 Retire los tornillos del motor J y las arandelas del motor R desde la parte inferior de la carcas...

Page 29: ...bles conductores y aseg rese de jalarlos completamente a trav s de la parte superior de la varilla Comience en la parte SUPERIOR de la bola para colgar en la varilla y mida 20 32 cm de cable conductor...

Page 30: ...no se utilizan en este tipo de instalaci n MONTAJE DEL VENTILADOR EN ESTILO CERRADO 1 C Ranura Leng eta 6 A Cubierta de la base B 1 B Si decidi cortar los cables conductores en el paso 4 pele 1 27 cm...

Page 31: ...de la base B 4 3 D 3 B D Retire los otros tornillos del motor J y la arandela del motor R de la parte superior de la carcasa del motor D Leng eta C 4 2 B Pase los cables hacia arriba a trav s del ori...

Page 32: ...a casa no son de los mismos colores que se mencionan en los siguientes pasos det ngase de inmediato Se recomienda que un electricista profesional determine el cableado adecuado Escoja el diagrama de c...

Page 33: ...CC Conector de cables E3 x 4 Aditamentos utilizados CC CC 2 CC 1b VENTILADOR CONTROLADO POR CADENA DE TIRO Y LUZ CONTROLADA POR INTERRUPTOR DE PARED Conecte el cable NEGRO del ventilador al cable NEG...

Page 34: ...enga en cuenta la etiqueta que marca ESTE LADO HACIA ARRIBA Alinee las estacas en el brazo del aspa H con los tornillos de las aspas AA asegurando el brazo del aspa H al aspa G y apriete los tornillos...

Page 35: ...a varilla roscada de la parte superior del soporte del kit de iluminaci n F Perfore la tapa central N de la tapa de la carcasa del interruptor T con un destornillador no se incluye Pase con cuidado lo...

Page 36: ...t de iluminaci n S PRECAUCI N NO utilice destornillador ni herramientas el ctricas para apretar los tornillos del soporte del kit de iluminaci n S El vidrio se romper APRIETE A MANO SOLAMENTE Nota NO...

Page 37: ...ufes est n conectados completamente Alinee los orificios de la carcasa del interruptor T con los orificios de la placa de la carcasa del interruptor Vuelva a insertar los tornillos de la placa de la c...

Page 38: ...a la posici n OFF apagado que apaga el ventilador 1 2 Utilice el interruptor de reversa del ventilador ubicado en la carcasa del interruptor T para optimizar el rendimiento de su ventilador seg n la e...

Page 39: ...nte que puede ayudar a mover el aire caliente estancado fuera del rea del techo Al menos dos veces al a o baje la base B para revisar el ensamble de la varilla A y luego apriete todos los tornillos en...

Page 40: ...o excesivo 1 Las aspas est n flojas 2 Los brazos de las aspas no est n ajustados correctamente 3 Las aspas no est n equilibradas 4 El ventilador no est bien colocado 5 El ventilador est demasiado cerc...

Page 41: ...ser responsabilidad del comprador El distribuidor no asume ning n tipo de responsabilidad por la instalaci n del ventilador durante la garant a limitada de por vida Cualquier servicio realizado por un...

Page 42: ...EZAS DE REPUESTO Para obtener piezas de repuesto llame a nuestro Departamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6 p m y los viernes de 8 a m a 5 p m hora est ndar d...

Reviews: