background image

15

       

CAUTION:

 The remote control transmitter can be programmed to multiple receivers or fans. 

If this is not desired, turn wall switch off to any other programmable receiver or fan.

OPERATING INSTRUCTIONS

FCC Compliance Notice for Remote Control

Modifications not approved by the party responsible for compliance could void the user's authority 
to operate the equipment.

*NOTE: This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures:

        *      Reorient or relocate the receiving antenna.
        *      Increase the separation between the equipment and receiver.
        *      Connect the equipment into an outlet on a circuit different from that to which the
 

     receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Remove battery cover from back of remote 
control transmitter in remote pack (P). Install 
battery from remote pack (P) with positive (+) 
end toward top of remote control transmitter. 

Replace battery cover on remote control 
transmitter.

        

WARNING

Choking Hazard

 - Small parts.

Keep battery away from children.

 1. 

(back

side)

1

Battery

Cover

P

       

CAUTION:

 “DO NOT DISPOSE OF BATTERIES IN FIRE, BATTERIES MAY EXPLODE OR 

LEAK.” - When disposing of household alkaline batteries, it is best to check with your local and 
state recycling or household hazardous waste coordinators concerning the specifics of the 
program in your area. You may also locate a recycling center by calling 1-800-8-BATTERY or 
1-877-2-RECYCLE or visit www.epa.gov/epawaste/index.htm or www.earth911.org for more 
information.

Remote

Control

Transmitter

Battery

Summary of Contents for TG44BNK3D1RC

Page 1: ...RE Serial Number Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST...

Page 2: ...t must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial cause for return Make sure all electrical connections comply with local codes ordin...

Page 3: ...ponding fan lead wires consult an electrician for the proper size wire connectors to use To reduce the risk of fire or electrical shock do not use the fan with any solid state speed control device or...

Page 4: ...ting Screw 4 preassembled H Motor Screw 6 preassembled I Lock Washer preassembled 6 J Blade 3 DESCRIPTION PART QUANTITY DESCRIPTION PART QUANTITY K Glass Shade 1 L Pin preassembled 1 M Clip preassembl...

Page 5: ...ls Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wi...

Page 6: ...luded Angle style mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Closemount mounting is more suitable for ceilings lowe...

Page 7: ...holes in blade arm located inside of motor Attach blade J with 3 blade screws AA and fiber washers BB Repeat for remaining blades J Note Make sure to completely secure each blade J before proceeding...

Page 8: ...ANT If using the angle mount make sure open end of mounting bracket C is installed facing the higher point of the ceiling and ensure the ceiling angle is not steeper than 19 8 For DOWNROD STYLE FAN MO...

Page 9: ...anner Take the lead wires and make sure you have pulled them all the way through the top of the downrod Start at the TOP of the hanging ball on the downrod and measure 8 in of lead wire and then cut t...

Page 10: ...in Step 4 strip 1 2 in of insulation from end of each wire WHITE BLACK GREEN and BLUE Twist stripped ends of each strand of wire within the insulation with pliers not included Install hanging ball of...

Page 11: ...D Remove every other motor screw H and lock washer I from top of motor housing D 2 Pull wires up through hole in the middle of the canopy B Align larger holes in canopy B with 3 screws in top of moto...

Page 12: ...ections for remote control operation as detailed below and in the figure For each wire connection use one of the wire connectors CC making sure to screw wire connector CC on in a clockwise direction C...

Page 13: ...r x 4 CC 3 Gently slide remote control receiver O flat side up into mounting bracket C Turn spliced taped wires upward and gently push wires and wire connectors CC into outlet box Let antenna from rem...

Page 14: ...on Closemount Option 2 Align slots on glass shade K with protrusions on underside of motor housing D Turn glass shade K clockwise until it no longer turns NOTE Pull down gently on the glass shade K to...

Page 15: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separ...

Page 16: ...fan MEDIUM speed 1 button for fan LOW speed 0 button to turn fan OFF button to turn light ON or OFF Tap button quickly to turn lights off or on Hold button down to increase or decrease lights If you...

Page 17: ...g the reverse switch in the RIGHT position will result in upward airflow that can help move stagnant hot air off the ceiling area At least twice each year lower canopy B to check downrod A assembly an...

Page 18: ...speed control device 4 Allow fan a break in period of a few days especially when running the fan at Medium and High speeds Excessive wobbling 1 Blades are loose 2 Unbalanced blades 3 Fan not securely...

Page 19: ...e warranty Any service performed by an unauthorized person will render the warranty invalid Due to varying climatic conditions this warranty does not cover changes in brass finish rusting pitting tarn...

Reviews: