18
Button 6 – menu scroll
Speed/pressure down
c
Engine start/stop
4.4.4. Radio Control layout
4.5. Running the Engine (Manual Mode)
If your machine is fitted with a radio remote control go to section 4.6.
(H&S Sections 3, 4, 8,
9, 11, 15, and 16)
Tank water level
Ensure you have an adequate water supply and that the water tank is filled to the ball valve
shut off level.
If your machine is fitted with a radio remote control go to section 4.6.
1. Switch on unit using toggle switch.
2. The control system will now go through a prestart (glow plugs).
3. Enter password ‘2010’ to enter.
4. You will now enter the run screen.
5. Press the engine start button.
6. The engine will now start and run in idle.
7. The user can now increase and decrease the speed of the engine using the engine up
and down speed.
8. Increase the speed of the engine and when it is safe to turn the water on, press the
water on button.
9. The engine speed and pressure can now be increased and decreased using speed up
and speed down button.
10. Radio mode will not operate when manual mode is selected.
Radio control screen
cc
Water on/off
cc
Speed/pressure up
cc
Button 5 – menu scroll
cc
NOTICE
: Do NOT allow unfiltered water into the pump.