5
3. Installation of Borer device
Setting of Blade holding bracket
1.Temporally set Cap screw M3x5 and Cap screw M4x10 to
Blade holding bracket.
Cap screw M3x5 should not be seen from hole of bracket.
2. Insert Borer blade into hole of Blade holding bracket as
photo below and fix by Cap screw M4x10.
* As tip of Borer blade is very sharp, please handle with care.
Installation
* Borer device should be installed on Needle no.15.
1. Move moving head to the position which 1
th
needle is
active.
Take Thread guide plate B, Front panel, Front panel, Front
panel (Lower) out.
Please refer to Maintenance manual [ 3-2-11 Exchange /
Adjustment of pressure foot ].
2. Take items listed below out from 15
th
needle bar.
Please refer to Maintenance Manual [ 3-2-11 Exchange /
Adjustment of pressure foot ].
* Needle
* Needle holder
* Cushion
* Pressure foot
Cap screw M3x5
Cap screw M4x10
Screw should not be seen
Same level
Cap screw M4x10
Needle holder
Needle
Pressure foot
Cushion
Front panel (Lower)
Thread guide plate B
Front panel