background image

 

 

 

ASSEMBLY AND USER INSTRUCTIONS 

 

FOR 

 

OUTDOOR BUILT-IN GAS FIRE BURNER KIT 

 

Your  new  SR2201BI/I2+,  SRR2201BI/I2+  &  4001BIS/I2+,  SR4001BIR/I2+    BUILT-IN  GAS  FIRE 
BURNER  KIT  is  made  from  the  highest  quality  materials,  and  produced  under  strict  manufacturing 
controls. 
 
Please  read  the  Instructions  for  assembly  before  commencing,  and  follow  the  instructions  for  use 
carefully. We congratulate  you  on  your  decision to  buy this  outdoor  built-in  gas fire  burner kit  and  wish 
you great fun when warming with it. 

 

PLEASE READ THESE SAFETY INSTRUCTIONS 

 

IN FULL BEFORE COMMENCING ASSEMBLY. 

 

Important Safety instructions 

 

The built-in gas fire burner kit is safe and easy to use. The following rules must be followed. 
 
1.  Ensure that the unit has been assembled correctly according to the instructions. 
2.  Never  loosen,  or  allow  the  gas  connection  to  become  loose.  Should  this  happen, 

immediately  ensure  that  the  gas  is  turned  off  at  the  cylinder  or  main  shut  off  valve  of  city 
network gas, and then re-check the security of the connection. 

3.  The appliance shall be kept away from flammable materials.  
4.  Read the Users instruction, Sections, and instructions written on the  built-in gas fire burner 

kit, refer to them whenever necessary. 

5.  Never leave the built-in gas fire burner kit unattended while using. 
6.  In the event of a gas leak, the appliance shall not be used or if alight, turn off gas supply at 

the LPG cylinder or the nearest main shut off valve of city network gas. And the appliance 
shall be investigated and rectified before it is used again. 

7.  Keep children well clear while  built-in gas fire burner kit is in use and after use until it has 

cooled. 

8.  Keep  warming  area,  1m  away  from  the  appliance,  clear  of  combustible  materials  and/or 

liquids. 

9.  Never obstruct free flow of air to the built-in gas fire burner kit, or alter/adapt the built-in gas 

fire burner kit to suit any other situation. 

10.  SR/R2201BI  &  SR4001BIS/R:  A  hose  conforming  to  the  national  standard  must  be 

connected at one end to the LPG regulator and at the other to the fire pit nipple using hose 
clips. The hose length is 1m.  
SR/R2  &  SR4001BIS/R/I2+:

 

A  hose  conforming  to  the  national  standard must  be 

connected at one end to the main shut off valve of city network gas and at the other to the 
fire pit inlet with a national standard NG connector. For the hose exposed, please be sure to 
use  (a)  rubber/PVC  layer(s)  to  cover  on  it  to  prevent  people  from  stumbling.  The  proper 
rubber/PVC layers are available from the same dealer or qualified installer. 
The material of any description should not be thrown on to the fuel bed.  
The appliance should not be used in bathroom or bedrooms. 
The appliance is only intended to be used as secondary heating. 

Summary of Contents for SR2201BI/I2 Plus

Page 1: ...r their mixture at 30mbar Injector SR2201BI I2 SRR2201BI I2 1 2 mm SR4001BIS I2 SR4001BIR I2 1 65mm AT DE SK CH Cat I3 B P 50 Butane propane or their mixture at 50mbar Injector SR2201BI I2 SRR2201BI I...

Page 2: ...r kit unattended while using 6 In the event of a gas leak the appliance shall not be used or if alight turn off gas supply at the LPG cylinder or the nearest main shut off valve of city network gas An...

Page 3: ...ce The dress guard is not supplied with the appliance the installer shall inform the user of the local rules in force and advise the fitting of the same dealer s or qualified installer s dress guard H...

Page 4: ...I2E I2E 3 0mm 13 kW 946 g h The marking on the injector for example 1 20 indicates that the size of injector is 1 20mm LP Gas Regulator A gas regulator confirming to the national standard must be fit...

Page 5: ...Igniter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M...

Page 6: ...iter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M6F41...

Page 7: ...6 SR2201BI I2 SR4001BIS I2 series exploded...

Page 8: ...7 SRR2201BI I2 SR4001BIR I2 series exploded...

Page 9: ...d inlet fitting as shown in FIG 01 FIG 02 below SR2201BII2 SRR2201BII2 SR4001BISI2 SR4001BIRI2 Attach the hose to the manifold inlet fitting with a national standard NG connector and secure the hose t...

Page 10: ...rner kit onto the opening of your wooden table as shown in FIG 01 NOTE You may need to use and attach the optional table support bracket kit as shown in FIG 02 to secure the slats you saw off Adjust a...

Page 11: ...perpendicular to the igniter box Lay the other logs in a teepee configuration over the first log It is important that the logs not lay directly on top of the burner By blocking the burner it will imp...

Page 12: ...11 SR4001BIS I2 SR4001BIR I2...

Page 13: ...e ground with screw Attach the manifold inlet fitting with the national standard NG connector supplied Connection of the NG supply to the appliance inlet should be made by a qualified installer Note F...

Page 14: ...NSTRUCTIONS 74BUINSTALLATION OF THE LID When the appliance is not in use disconnect and take off the logs and close the lid to use as a normal table NOTE Be sure unit is cool before touching any of th...

Page 15: ...ES Turn off the gas supply at the cylinder or main shut off valve of city network gas Do not try to light any appliance Do not touch any electrical switches Do not use any phone including cellular pho...

Page 16: ...e area clear and free from combustible materials gasoline and other flammable vapors and liquids Installation and repair should be done by a qualified service person The appliance should be inspected...

Page 17: ...regulator for details regarding fitting 3 Test for gas leaks Do a leak test each time the cylinder is installed whether or not it has been filled Check all other joints at least once a year lf the hos...

Page 18: ...areas where the hose may be subjected to accidental damage 7 Open tank valve fully Turn the on off valve at the unit to the off position to pressurize the hose assembly Use a soapy water solution to...

Page 19: ...y part has been under water Immediately call a qualified service technician to water WHAT TO DO IF YOU SMELL GAS Turn off the gas supply at the cylinder or main shut off valve of city network gas Do n...

Page 20: ...s to ensure it is not cracked or damaged in any way INSPECTION AFTER REPAIR Any repairs must be performed by a qualified installer service agency or your gas provider 1 Check all the joints 2 Smell al...

Reviews: