background image

6

 

 

Safety & Maintenance

 

      

Unit will become warm to the touch 

and possibly hot when in use.

 

 

Unit MUST be securely mounted to a bench, heavy duty cart, or   

 

other sturdy surface before using.  The 

3/8” 

fastening holes in base 

units can be used to secure unit.

 

 

 

No flammable materials(i.e. solvents) should be placed near or inside 

the X

-

20 unit. 

 

 

The location of the X

-

20 unit should provide enough clearance for the 

swinging lid to open.

 

 

 

A suitable 15 AMP, 115 VAC circuit should be within 

5’ 

of the X

-

20  

unit.

 

Note: This device uses 440 WATTS at 120 VAC @ 60 HZ. Users in a foreign country 

are responsible for procuring the proper converter that meet the standards and require-

ments for use. 

 

           

 

 

A sufficient clean, dry air supply should be available to pressurize the 

unit.

 

 

 

Use 

DANGER DO NOT OPEN

” 

tag on each machine while they 

are under pressure. 

 

 

 

Clean debris from top of shelf and underneath on a daily basis.

 

 

 

Check fittings and valves for pressure leaks on a weekly basis. 

 

 

 

Grease the tips and threads of 6 clamping bolts and check cover align-

ment on a monthly basis.(See Pg. 12)

 

 

Summary of Contents for X-11

Page 1: ...The User Guide to The X 20 Molding Chamber...

Page 2: ...verview of Features Specifications 3 Features 4 5 Safety Maintenance 6 Initial Startup Procedure 7 Using the X 20 8 9 Using the Heating System 10 Temperature Conversion Formulas Chart 11 Cover Realign...

Page 3: ...on 1 4 Turn Ball Valve Ergonomically Designed Cover Industrial Standard Air Stud Ready level Mounting Brackets 11x28 Removable Casting Shelf Air Flow Diverter X 11 Molding Chamber shown External Dimen...

Page 4: ...80 F 82 C Pressure Relief Valve Lets out a quick release of air be fore the tank s maximum pressure is reached 110 psi Temperature Control Digital user control with variable output for precision moldi...

Page 5: ...ble Shelf 12x28 stainless steel removable shelf The height from the shelf to the ceiling of the tank is 9 5 Air Flow Diverter Disperses the inflow of air preventing the air from disturbing items on th...

Page 6: ...table 15 AMP 115 VAC circuit should be within 5 of the X 20 unit Note This device uses 440 WATTS at 120 VAC 60 HZ Users in a foreign country are responsible for procuring the proper converter that mee...

Page 7: ...ws from the box and unbolting the brackets from the bottom 2 Place the unit on a sturdy level surface close to electrical and air supply 4 Loosen the swing clamps 6 and open the lid 3 Secure the X 20...

Page 8: ...inch pounds may distort the gasket and cause damage to the sealing surface 4 Slowly open the ball valve until desired air pressure is reached 70 80 PSI is recommended 1 Place molds and parts on the sh...

Page 9: ...ing clamps using an adjustable wrench NOTICE Operating the X 20 with both heat and pressure causes expansion and contraction of sealing surfaces throughout the chamber Under these conditions it is nor...

Page 10: ...stem is digitally controlled and unlike similar devices on the market heated from the inside of the chamber The digital controller allows the user to easily set the tank s temperature while displaying...

Page 11: ...160 320 0 32 165 329 5 41 170 338 10 50 175 347 15 59 180 356 20 68 185 365 25 77 190 374 30 86 195 383 35 95 200 392 40 104 205 401 45 113 210 410 50 122 215 419 55 131 220 428 60 140 225 437 65 149...

Page 12: ...EXCEPT for the clamp on the hinge arm Should remain slightly loosened 3 Tighten down the 15 16 vertical bolts that attach the hinge arm to the side of the tank 4 Using a large flat jaw adjustable wre...

Page 13: ...Ball Valve Y109A 400 Watt Heater Y110A 3 Fan Y111 Pressure Gauge Y116 1 4 Brass Elbow Y117 1 4 Brass Tee Y118 3 8 Brass Plug w Holes Y121 18 Hose Clamp Y122 3 8 Hexbolt Y123 3 8 Hexnut Y124 3 8 Flat W...