• If the user use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages.
• To prevent electric shock or equipment failure, please do not turn on the
power until completing wiring.
• Never disassemble, modify, or repair the product. There is a possibility of a
malfunction, an electric shock, or a risk of fire.
• Please turn off the power when mounting/dismounting of the product. This
is a cause of an electric shock, a malfunction, or failure.
• To prevent damage or failure of this product, please supply the rated power voltage.
• Since this is not explosion-proof structure, please do not use in a place
where combustible or explosive gas is around.
• Since there is a possibility of an electric shock, please use the product as
mounted on a panel while the power is being supplied.
WARNING
CAUTION
Specification
Power supply voltage
5 V d.c.
12 - 24 V d.c.
Power consumption
Approx. 3 W
Approx. 5 W
Insulation resistance 10
㏁
min
( 500 V d.c.)
Dielectric strenght 1,500 V AC for
1 min (power terminal - input terminal)
Noise resistance
Power supply terminal normal mode
±
200 V
Power supply terminal common mode
±
500 V
Vibration durability
10 - 55 ㎐ Peak amplitude for 2 hours each in X, Y, Z directions
Shock durability
300
㎨
(Approx 30 G)
Ambient temperature 0 ~ 50 ℃
Ambient humidity
35 ~ 85 % RH
Storage temperature -10 ~ 70 ℃
Suffix code
Model
Code
Description
BA1-
☐ ☐ ☐ ☐
Mini DC indicator (48 × 24
㎜
)
Input
D
10
DC voltage (voltmeter)
20
DC current (ammeter)
11
DC voltmeter (1 - 5 V DC)
21
DC ammeter (4 - 20
㎃
DC)
Range code
1
Refer to the measurement range code
Power supply voltage
- No indication: 5 V d.c.
A 12 - 24 V d.c.
Measurement range
█
DC voltage
█
DC voltage
█
DC current
█
DC current
Model
Measurement range Resolving power Input impedance Max allowable input voltage
BA1-D101
199.9
㎷
100
㎶
100
㏀
70
V
BA1-D102
1.999
V
1
㎷
1
㏁
100
V
BA1-D103
19.99
V
10
㎷
1
㏁
250
V
BA1-D104
199.9
V
100
㎷
10
㏁
300
V
Model
Input
Display range
Input impedance Max allowable input voltage
BA1-D111
1 - 5 V DC
50.0
100
㏀
100
V
BA1-D112
100.0
100
㏀
100
V
BA1-D113
199.9
100
㏀
100
V
Model
Input
Display range
Input impedance Max allowable input current
BA1-D211
4 - 20
㎃
DC
50.0
25
Ω
150
㎃
BA1-D212
100.0
50
Ω
150
㎃
BA1-D213
199.9
100
Ω
150
㎃
Model
Measurement range Resolving power Input impedance Max allowable input current
BA1-D201
199.9
㎂
0.1
㎂
1
㏀
1
㎃
BA1-D202
1.999
㎃
1
㎂
100
Ω
50
㎃
BA1-D203
19.99
㎃
10
㎂
10
Ω
150
㎃
BA1-D204
199.9
㎃
100
㎂
1
Ω
300
㎃
BA1-D205
1.999
A
1
㎃
Use shunt
(secondary voltage 50
㎷
)
BA1-D206
19.99
A
10
㎃
BA1-D207
199.9
A
100
㎃
BA1-D208
1999
A
1
A
※
Accuracy :
±
0.2 % of indication value
±
1 digit (23 ℃
±
5 ℃)
※
Accuracy :
±
0.2 % of indication value
±
1 digit (23 ℃
±
5 ℃)
※
Accuracy :
±
0.2 % of indication value
±
1 digit (23 ℃
±
5 ℃)
※
Accuracy :
±
0.2 % of indication value
±
1 digit (23 ℃
±
5 ℃)
• The contents of the instruction manual are subjective to change without prior notice.
• Please make sure that the specification is the same as what you have ordered.
• Please make sure that the product is not damaged during shipping.
• Please use this product in a place where corrosive gas (such as harmful
gas, ammonia, etc.) and flammable gas do not occur.
• Please use this product in a place where there is no direct vibration and a
large physical impact to the product.
• Please use this product in a place where there is no water, oil, chemicals,
steam, dust, salt, iron or others (Contamination class 1 or 2).
• Please do not wipe this product with organic solvents such as alcohol,
benzene and others. (Please use mild detergent)
• Please avoid places where excessive amounts of inductive interference
and electrostatic and magnetic noise occur.
• Please avoid places where heat accumulation occurs due to direct sunlight or radiant heat.
• Please use this product in a place where the elevation is below 2,000 m.
• Please make sure to inspect the product if exposed to water since there is
a possibility of an electric leakage or a risk of fire.
• It is effective against noise if making the power lines of the product the twisted pair wiring.
• Please do not connect anything to the unused terminals.
• Please connect wires properly after making sure the polarity of terminal.
• Please install a switch or break near the operator to facilitate its operation.
• Write down on a label that the operation of circuit breaker or switch
disconnects the power since the devise is installed.
• In order to use this product properly and safely, we recommend periodic maintenance.
• Some parts of this product have limited expected life span and aged deterioration.
• The warranty of this product (including accessories) is 1 year only when it
is used for the purpose it was intended under normal condition.
Digital panelmeter
BA 1
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
INSTRUCTION MANUAL
MF0204KE170807
HANYOUNGNUX CO.,LTD
HEAD OFFICE
28, Gilpa-ro 71 beon-gil, Nam-gu, Incheon, Korea
TEL : (82-32)876-4697 FAX : (82-32)876-4696
http://www.hynux.com
Do not touch or contact the input/output terminals because it may cause
electric shock.
DANGER
Safety information
Before using the product, please read the safety information thoroughly and use it properly.
Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury
WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury
DANGER
WARNING
CAUTION
※ Within the measurement range, range code is 101 for the model BA1-D101