Thank you for purchasing HANYOUNG NUX Co.,Ltd. product.
Please check whether the product you purchased is the exactly same
as you ordered. Before using this product, please read instruction
manual carefully.
Specification
MA0904E081126
1. The contents in this manual may changed without prior notice.
2. Please check whether delivered product is same as what you have asked for. (check
model name and specifications)
3. Please check whether any parts have been damaged during delivery
4. Please avoid place where corrosive gas(especially noxious gas, ammonia and etc)
and inflammable gas exist
5. Please avoid place where vibration and impaction carry into the product directly.
6. Please avoid place where liquid, oil, medical substances, dust, salt or iron contents
exist(avoid place of pollution level 1 or 2)
7. Please avoid place where excessive induction trouble, static electricity or magnetic noise
occur
8. Please avoid place with possible thermal accumulation which caused by direct sunlight
or heat radiation.
9. Please use compensation lead wires in case of thermo couple input (using normal or
general wire will cause temperature error)
10.In case of inputting RTD, please use small lead wire resistance and no resistant
difference within 3 wires. (temperature error occur when resistant value different among
3 wires)
11.In order to avoid from effect of induction noise when using input signal line, avoid main
power line, power line and load line.
12.Separate input signal line and output signal line. If separating those two lines is
impossible then use shield line for input signal line.
13.For thermo couple, please use non-earthing sensor. (In case of using earthing sensor,
malfunction of device might occur due to electric leakage)
14.If there is an excessive noise from power supply, it is recommended to use insulating
transformer and noise filter. The noise filter must be attached to back side of the panel
and wire of output side filter and power supply terminal should be as short as possible.
15.Instrument power line should be arranged very closely in order to get noise efficiency
16.When connecting this device to a panel, please use a circuit breaker or switch approved
by IEC947-1 or IEC947-3.
17.Because switch or circuit breaker has been installed, please write down about
disconnection of power on a panel if switch or circuit breaker operates properly.
18.Some parts of this product have limited life and others vary depending on their usage.
19.If product is properly used, warranty period is one year including parts
20.When power is ON, the preparation period of contact output is required. In case of
using signals of external interlock circuit, use a delay relay
21.In case of break down of replaced instrument, please check for compatibility before
replaces it with prepared instrument. Although specifications might be same but
difference of setting parameter can cause unwanted operation.
Safety Information
1. Please input proper power voltage in order to prevent product to break down or get
damaged.
2. Please avoid place where inflammable or explosive gas exist. This product is not
explosion-proof construction.
3. Please turn off power before attach and detach this product. It may cause electric shock,
malfunction and break down
4.Please do not touch or contact the input/output terminals. It may cause electric shock
WARNING
CAUTION
Please read safety information carefully before using this product in order to use it
properly. Safety information described in this manual contains important contents
regarding safety. So users must follow following instructions accordingly. Safety
information is composed of WARNING and CAUTION.
TP3
HEAD / OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL: (82-32)876-4697 FAX : (82-32)876-4696
Suffix code
Dimensions and Panel Cutout
Name Of Each Parts
(Unit : mm)
Code
Model
Content
Size : 96
48
100
Only for indication
K (-50 ~ 1200
)
J (-50 ~ 800
)
R (0 ~ 1700
)
Pt 100
(-100 ~ 400
)
100 - 240 V a.c, 50 - 60 Hz
(Unit :
)
(CA)
(IC)
(PR)
DIN Pt100
TP3
Adjusting movement
Input
Power
K
J
R
P
0
100 - 240 V a.c(
10 %), 50 - 60 Hz
Below 5 VA
thermo couple : K, J, R
: DIN Pt100
Thermo couple :
0.5% of displayed value + 1 Digit or
3
(Choose bigger value).
In case of using R input : 0 ~ 199
0.5
:
0.5% of displayed value
1 digit or
2
(Choose
bigger value).
Only for indication (5 Chanel)
Digital method by using selecting button (
*
)
96
48
100
Temperature display is automatic from channel 1 to 5 or
temperature display of fixed channel.
Revise temperature offset within each channel.
Below 0
~ 50
/ 35 ~ 85 % R.H.
Power Voltage
Power Consumption
Input
Accuracy
Control
Setting method
Product size
Other functions
AmbientTemp.
Humidity
"채널 자동전환"
46
Connections