HANYOUNG NUX PFB-R Instruction Manual Download Page 2

Model

Code

Content

PFB-

□ □

10 bit A/D, Bar display

Light source

R

Red LED

External output

N

NPN Open collector

P

PNP Open collector

▍Suffix code

▍Specification

Optical Fiber Sensor 

PFB-R

Thank you for purchasing Hanyoung Nux products. Please read the instruction 

manual carefully before using this product, and use the product correctly. 

Also, please keep this instruction manual where you can view it any time.  

INSTRUCTION MANUAL

▍Safety information

   

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

   

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

   

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage

Please read the safety information carefully before the use, and use the product correctly.

The alerts declared in the manual are classified into 

Danger, Warning

 and 

Caution

 according to their importance

• The input/output terminals are subject to electric shock risk. Never let the input/output  terminals come in  

   contact with  your body  or conductive substances.

DANGER

• The contents of this manual may be changed without prior notification.

• If you use the product with methods other than specified by the 

   manufacturer, there may be bodily injuries or property damages. 

• Avoid continuously switching the power source On and Off.

• Use a dry cloth to wipe off the substance when cleaning the 

   lens or cases. Never use thinner or organic solvents.

•  Do not use this product at any place with much dust, vibration or impact.

• Before inserting power source, make sure that the circuit wiring 

   is properly connected.

• In the case of wiring loaded inductors such as DC Relay and 

   others to output, use diode, varistor and others to prevent surge. 

• To avoid malfunction caused by noise, do not put high voltage 

   or power line with sensor wire in a same conduit.  

• Make its wiring be shorter as possible and wire extension shall 

   be within 30 m.

• Do not apply a strong tension to the fiber optic cable.

• Do not curve the fiber optic cable over tolerable bending.

• Do not make any scratch on the cable.

• Consider the fact that the sensing distance may be varied 

   in accordance with the size, color, surface condition, 

   material, glossy, non-glossy or others of a sensing object.

• Prevent strong disturbance light such as sunlight and 

   others which directly enter into the directional angle of 

   the sensor by putting a glare shield.

• In the case of using multiple sensors (more than 2 sensors), there 

   is a possibility of malfunction caused by mutual interference so, 

   for Through-Beam type, sensors shall be installed in a divergent 

   way or there shall be proper distance between them.

• When using the Switching Power Supply as the power source, 

   earth the Frame Ground (F.G) terminal and be sure to connect the 

   noise-eliminating condenser between 0 V and F.G.

• To prevent defection or malfunction of this product, 

  supply proper power voltage in accordance with the rating.

• Since this product is not designed with explosion protective 

   structure, do not use it at any place with  flammable or explosive gas.

• Remove this product while the power is off. Otherwise, 

   it may cause malfunction or electric shock.

WARNING

CAUTION

Model

PFB-RN

PFB-RP

Sensing method

Through beam type, reflection type ( By the fiber cable )

Sensing distance

By the fiber sensor

Power supply voltage

12 - 24 V DC  ± 10 % ( Ripple less than 10% )

Current consumption

max 20 ㎃

 Control output

NPN open collector output, max 100 ㎃ (30 VDC) PNP open collector output, max 100 ㎃ (30 VDC)

Output action

L.ON, D.ON selection

Time function

NORMAL, ON-Delay, OFF-Delay (Delay time 40 ㎳ fixed)

 Responce time

max 1 ㎳

Hysteresis

Reflection type : Less than 10% of the sensing distance

Light source (wave length)

Infrared lightening LED (660 ㎚)

LED

Displayed by Bar LED

Sensitivity adjustment

Auto teaching/manual installution by using the set button

Protective circuit

Built in the reversed power supply connection protective circuit and output short 

protective circuit and motual interference prevention

Ambient illumination

Sunlight : max 11,000 Lux, Incandescent lamp : max 3,000 Lux

Ambient temperature

-10 ~ 55 ℃ (Surrounding storage temperature : -25 ~ 70 ℃)

Ambient humidity

35 ~ 85 % R.H. (With no condensation)

Protective structure

IP 40 (IEC)

Insulation resistance

min 20 ㏁ (500 VDC between the code and case, between the adjustment switch and case)

Dielectric strength

1000 VAC, 50/60 ㎐ for 1 min

Vibration resistance

10 - 55 Hz double amplitude 1.5 ㎜, for 2 hours each in X, Y and Z directions

Shock resistance

500 ㎨  3 times each in X, Y and Z directions

Connection method

Code extended type, Code length : 2 m. No.of lines : 5 P, thickness : Ø4 ㎜. DIN rail installation structure

Material

Case : heat resistance ABS

Weight

Approx. 150g (Included the weight of box and fixing bracket)

■ NPN type

Wiring diagram

■ Slide switch1 setting

Installation and instruction

Function

Information

External teaching ( E.T )

External synchronous ( E.S )

selectable

• Set the slide switch 1 at SET

• Pressing the ◁ (M.T/E) button instantly will switch from E.T to E.S and save the setting.  

   ( selected  LED will flicker )

 CH1/CH2 selectable

• Set the slide switch 1 at SET

• Pressing the ▷ (A.T/C) button instantly will switch from CH1 to CH2 and save the setting.  

   ( CH1 : 3 KHz, CH2 :2.8 KHz )

L.ON selectable

 Select the slide switch 1 as L.ON

D.ON selectable

 Select the slide switch 1 as D.ON

Function

Information

OF.D ( OFF-DELAY )

• Select the slide switch 2 as OF.D

   40 ms delayed when operating the control output OFF

 NOR ( NORMAL )

• Select the slide switch 2 as NOR

   No delay time when operating the control output

ON.D(ON-DELAY)

• Select the slide switch 2 as ON.D

   40 ms delayed when control output is in ON action

■ Slide switch2 setting

• When slide switch 1 SET mode is selected as external teaching (E.T)

• Delay setting and Output operation 

 T = 40 ㎳

ON

OFF

ON

OFF

HIGH

LOW

Approx. 40 ms

ON

OFF

ON

OFF

HIGH

LOW

Differential synchronous

Interval synchronous

Sensing

Signal

External

Synchronous

Input

Control

Output

Light On

NORMAL

ON DELAY

T ON

T ON

T OFF

T OFF

OFF DELAY

ON/OFF DELAY

Dark On

Output

• When slide switch 1 SET mode is selected as external synchronous (E.S)

Function

Information

TRIG ( TRIGER )

• Select the slide switch 2 as TRIG

   control output becomes synchronous input and differential synchronous

 NOR ( NORMAL )

• Select the slide switch 2 as NOR

   Control output has no synchronization with synchronous input

GATE

• Select the slide switch 2 as GATE

   Control output becomes interval synchronization with synchronous input

ON

OFF

ON

OFF

HIGH

LOW

Approx. 40 ms

ON

OFF

ON

OFF

HIGH

LOW

Differential synchronous

Interval synchronous

Sensing

Signal

External

Synchronous

Input

Control

Output

Light On

NORMAL

ON DELAY

T ON

T ON

T OFF

T OFF

OFF DELAY

ON/OFF DELAY

Dark On

Output

■ 2 Contact teaching method

Operation level setting

There are two types in operation setting level which are 2 contact teaching and auto teaching. "2 contact teaching method" 

is the method that sets the operation level by teaching the 2 contacts when it is in state where sensing object is in presence 

and in absence.  This method is most widely used.  

■ How to use auto teaching

• Use auto teaching without stopping the line when set the operation  level in the state where sensing object is moving.

Function

Information

• Install the fiber within the sensing range.

• Pressing the ▷(AT/C) button for 3 sec will enter into the "auto operation level" setting mode. 

   Here BAR-LED and STB-LED start to flicker.

• It runs the auto teaching function automatically for approx 10sec and return to the operation  

   mode. Here BAR-LED and STB-LED stop flickering.  

   (this is only applied under the condition where sensing object moves at least twice in 10 sec) 

Order

Information

• Install the fiber within sensing range.

• Select the [slide switch 1] as L.ON (Light-on) side or D.ON (Dark-on) side.  

• Pressing the ◁(M.T/E) button for 3 sec will enter into the "operation level setting mode".  

   Here BAR-LED and STB-LED start to flicker.

 

• Pressing the ◁(M.T/E) button instantly when sensing object is not in presence 

   (max amount of  light state) will save the max value of light.  

 • Pressing the ▷(A.T/C) button instantly when sensing object is in presence (min amount of light state)

    will save the min value of light.

• Pressing any of two buttons for 3 sec will return to the operation mode.  

   Here, BAR-LED and STB-LED will stop flickering.

Through-beam type

Reflecting type

Through-beam type

Reflecting type

Name of parts

• Setting and operation selecting slide switch

    SET :  This is SETUP function which is used for setting the 

TIME and other functions

    L.ON :  Light ON operation mode which of control output 

becomes ON when an amount of light is more than 

the set value.   

    D.ON :  Dark ON operation mode which of control output becomes 

ON when an amount of light is less than the set value.

• Delay time selecting slide switch

    OFD :  OFF Delay which of when the input light level is OFF, 

output will become OFF due to the delay of 40 ms

    OND :  ON Delay which of when the input light level is ON, 

output will become ON due to the delay of 40 ms

    NOR :  Generate the output immediately depending on the 

input light state 

    TRIG :  With the increment of derivative running external 

input, it checks for the input light state and then 

generates the output (Delay Time setting possible)

    GATE :  It generates the output when the period running 

external input and input light become ON state.  

(AND circuit) 

■ PNP type

Dimension

10

7

9.83

66.8

30.0

35.8 DIN Rail

ø4.0 Cable L:2000

2-ø2.3

[ Unit : ㎜ ]

MK1701KE180824

28, Gilpa-ro 71beon-gil,  Michuhol-gu, 

Incheon, Korea TEL : +82-32-876-4697 

http://www.hynux.com

HANYOUNGNUX CO.,LTD