background image

3

4

※        ,         display is optional.

Parameter 1

Display

Description Default value

Set range

Remark

Average

delay count

Max :

set up the number of input 
for average measurement.

Min :

Peak auto

detect Hold

set up automatic holding 
when peak value measures.

Lock

set up lock fuction.

Parameter 2

Display

Description Default value

Set range

Remark

High Peak

Display

-

-

Display the max value 
among the measured values. 

Low Peak

Display

-

-

Display the min value among 
the measured values.

Output

High Set

Max :

Set up the high set value.

Min :

Output

Low Set

Max :

Set up the low set value.

Min :

Output Type 

Select

LL :

Set the comparative output 
mode.

HH :

LH :

HL :

IL :

HYS terisis

Max :

Set up the hysteresis.

Min :

Operation

mode

Output Operation

Explanation

H : Hysteresis

No output operation

Current indication value ≦           value,  
LO output becomes ON.             
Current indication value ≧           value, 
GO output becomes ON.
Current indication value ≧           value,   
HI output becomes ON.             
Current indication value ≦           value, 
GO output becomes ON.
Current indication value ≦            value,  

LO output becomes ON.             

Current indication value ≧            value,   

HI output becomes ON.

Current indication value ≺           ,          

GO output becomes ON.  
Current indication value ≧           value,  

LO output becomes ON.             

Current indication value ≧           value,   

HI output becomes ON.  

Current indication value ≺          and      

          , GO output becomes ON.
Same as the           operation but LO output will 
not operate under the initial setup value of          .  
It starts to operate from the next value of            .  

It does not operate under the initial

comparative output action (          )

How to set up the parameter

▒ Parameter1 (     Key - keep pushing the button(min 2 sec))

keep pushing     key(min 2 sec) and find the parameter 1 set up mode

1. Display the number 
   of average

Key

set up start

Key

set up start

Key

set up start

Key

Key

Key

        

        Key

     set up

        Key

     set up

        Key

     set up

25 (max. value)

1 (min. value)

OFF

OFF ON

H - Hd

L - Hd

E - Hd

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

Default value :

Default value :

Default value :

2. Automatically holding 
at the max mesurement

3. Set up the lock 
   function

▒ Lock key (     Key - keep pushing the button(min 2 sec))

▒ Parameter2 (     Key -shortly push the button (below 2 sec)

shortly push the     button(below 2 sec) and find the parameter 2 set up mode

Display function of 
the max input value

Display function of 
the min input value

Set up the max 

comparative output 

value

Set up the min 

comparative output 

value

Set the comparative 
output mode

Hysteresis Selection

Key

Key

Key

 Key

set up start

 Key

set up start

 Key

set up start

 Key

set up start

Key

Key

Key

Key

    max.

value default

    min.

value default

        Key

     set up

To move the position of the

number then press     key

To move the position of the

number then press     key

To move the position of the

number then press     key

        Key

     set up

        Key

     set up

        Key

     set up 

9.999 (set up the max comparative output value)

-1.999 (set up the mix comparative output value)

9.999 (set up the max comparative output value)

-1.999 (set up the mix comparative output value)

LL.ot

99 (max. value)
00 (min. value)

HH.ot

LH.ot

HL.ot

IL.ot

Display of the max 

input value

Display of the min 

input value

set up the max 

comparative output value

set up the min 

comparative output value

Set the comparative 

output mode

Default value : 01

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

Key - keep pushing the button(min 2 sec)

Key

Key   

set up start

Key   

set up start

Key   

set up start

Default value :

Default value :

Set value :

Set value :

Set value :

Set value :

Set value :

Set value :

        Key

     set up

        Key로

설정값 변경

        Key로

설정값 변경

        Key

     set up

OFF

ON

    Key

set up

completed

    Key 

set up

completed

※ every parameter set up is not available when the             on.

▒ How to change the parameter set value

Key - keep pushing the button(min 2 sec)

Key

Key   

set up start

Key   

set up start

Key   

set up start

Default value :

Default value :

Set value :

Set value :

Set value :

Set value :

Set value :

Set value :

        Key

     set up

        Key로

설정값 변경

        Key로

설정값 변경

        Key

     set up

OFF

ON

    Key

set up

completed

    Key 

set up

completed

1.  Pressing      key more than 2 sec within the RUN MODE will enter into the Parameter 1 and   
    pressing      key less than 2 sec will enter into the parameter 2.
2.  Able to select the parameter by pressing     ,      key and within the selected parameter, 
    parameter and set value repeatedly flickers in the display unit.
3.  Able to change the set value by pressing the      key and at this moment, set value flickers 
    in the display unit(when set value is 0, only the 0th digit of constant value flickers and displayed)
    When changing the setting of constant value, able to perform the position shifting by using      key.
   Example)

 When set value is constant, only 0th digit of the constant value will flicker in the display unit.  
 In order to change the value on 100th digit, press the     key 3 times.  Each time when users press 
the     key, position of the digit will shirt to the left and selected digit will flicker in the display unit.
When setting is completed, return to the parameter mode by pressing the      key.  At this moment, 
flickers  the parameter and set value repeatedly. Able to return to the RUN mode by pressing the      
     key again.

Error display code

Initializing set value

Push the button                sequancely with pushing the     .
And then          is displayed. When displaying          , push again the     button and the all 
default value is initialized.
(* Initializing set value is not available when            on.)

: Displayed when measuring input electrical pressure ecxeeds max input range.
: Displayed when measuring input electrical volatge ecxeeds max input range.
: Displayed when high comparative output set value is lower than low 
  comparative output set value.

▒ Retransmission output regarding the power factor display

▒ Retransmission fucntion (Auxiliary Output)

● Current output

    Generate 4 - 20 mA d.c for a present displayed value (resolving power 2000)

● Relay output (250 V a.c 5 A below) 1a × 3

※ Caution) PF3 is a power factor meter based on the cycle measurement method.
               It might be possible to be late input(max 2 sec) or not accurate when use in 
               below 5% of the rated voltage.

Summary of Contents for PF3

Page 1: ... 스위치나 차단기는 운전자가 조작이 용이하도록 가까운 거리에 설치하십시오 본 기기를 계속적으로 안전하게 사용하기 위하여 정기적인 보수를 권장합니다 본 기기의 탑재부품에는 수명이 있는 것과 경년 변화 하는 것이 있습니다 부속품을 포함한 본기기의 보증기간은 정상적으로 사용한 경우에 1년입니다 위 험 경 고 주 의 접속도 전 원 전 압 100 240 V a c 50 60 공용 허용 전압변동 범위 10 소 비 전 력 약6 VA 표 시 방 식 7 세그먼트 LED 표시 측 정 방 식 주기측정방식 COS Ø LEAD 0 1 1 LAG 0 1 표 시 주 기 0 5 2초 정격전류의 5 이하의 부하에서는 동작이 부정확하거나 표시주기가 느려질 수 있습니다 표 시 0 10 1 00 측 정 항 목 역률 COS φ 입 력 전 압 0...

Page 2: ...ey 로 설정 자릿수 이동 SHIFT KEY Key 로 설정 Key 로 설정 자릿수 이동 SHIFT KEY Key 로 설정 자릿수 이동 SHIFT KEY 9 999 비교출력 상한설정 최대값 1 999 비교출력 상한설정 최저값 9 999 비교출력 상한설정 최대값 1 999 비교출력 상한설정 최저값 LL ot 99 최대값 00 최저값 HH ot LH ot HL ot IL ot Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 입력최대값 표시 입력최저값 표시 비교출력 상한값 설정 비교출력 하한값 설정 비교출력 모드 설정 초기설정값 01 RUN MODE에서 KEY를 짧게 2초이상 누르면 LOCK 설정모드로 진입합니다 Key Key 설정완료 Key 설정시작 Key 설정시...

Page 3: ...1 LAG 0 1 Display cycle 0 5 2sec Operation may not be accurate or display cycle may become slow when the load is less than 5 of rated current Display range 0 10 1 00 Measurement list Power factor Cos φ Input voltage 0 220 V a c 50 60 Hz Input current 5 A 1 A external current transformer secondary current Accuracy 2 display range Hold function Hold and externally hold the max measurement value and ...

Page 4: ...the mix comparative output value LL ot 99 max value 00 min value HH ot LH ot HL ot IL ot Display of the max input value Display of the min input value set up the max comparative output value set up the min comparative output value Set the comparative output mode Default value 01 Key set up completed Key set up completed Key set up completed Key set up completed Key set up completed Key set up comp...