3
4
※ , display is optional.
Parameter 1
Display
Description Default value
Set range
Remark
Average
delay count
Max :
set up the number of input
for average measurement.
Min :
Peak auto
detect Hold
set up automatic holding
when peak value measures.
Lock
set up lock fuction.
Parameter 2
Display
Description Default value
Set range
Remark
High Peak
Display
-
-
Display the max value
among the measured values.
Low Peak
Display
-
-
Display the min value among
the measured values.
Output
High Set
Max :
Set up the high set value.
Min :
Output
Low Set
Max :
Set up the low set value.
Min :
Output Type
Select
LL :
Set the comparative output
mode.
HH :
LH :
HL :
IL :
HYS terisis
Max :
Set up the hysteresis.
Min :
Operation
mode
Output Operation
Explanation
H : Hysteresis
No output operation
Current indication value ≦ value,
LO output becomes ON.
Current indication value ≧ value,
GO output becomes ON.
Current indication value ≧ value,
HI output becomes ON.
Current indication value ≦ value,
GO output becomes ON.
Current indication value ≦ value,
LO output becomes ON.
Current indication value ≧ value,
HI output becomes ON.
Current indication value ≺ ,
GO output becomes ON.
Current indication value ≧ value,
LO output becomes ON.
Current indication value ≧ value,
HI output becomes ON.
Current indication value ≺ and
, GO output becomes ON.
Same as the operation but LO output will
not operate under the initial setup value of .
It starts to operate from the next value of .
It does not operate under the initial
comparative output action ( )
How to set up the parameter
▒ Parameter1 ( Key - keep pushing the button(min 2 sec))
keep pushing key(min 2 sec) and find the parameter 1 set up mode
1. Display the number
of average
Key
set up start
Key
set up start
Key
set up start
Key
Key
Key
Key
set up
Key
set up
Key
set up
25 (max. value)
1 (min. value)
OFF
OFF ON
H - Hd
L - Hd
E - Hd
Key
set up
completed
Key
set up
completed
Key
set up
completed
Default value :
Default value :
Default value :
2. Automatically holding
at the max mesurement
3. Set up the lock
function
▒ Lock key ( Key - keep pushing the button(min 2 sec))
▒ Parameter2 ( Key -shortly push the button (below 2 sec)
shortly push the button(below 2 sec) and find the parameter 2 set up mode
Display function of
the max input value
Display function of
the min input value
Set up the max
comparative output
value
Set up the min
comparative output
value
Set the comparative
output mode
Hysteresis Selection
Key
Key
Key
Key
set up start
Key
set up start
Key
set up start
Key
set up start
Key
Key
Key
Key
max.
value default
min.
value default
Key
set up
To move the position of the
number then press key
To move the position of the
number then press key
To move the position of the
number then press key
Key
set up
Key
set up
Key
set up
9.999 (set up the max comparative output value)
-1.999 (set up the mix comparative output value)
9.999 (set up the max comparative output value)
-1.999 (set up the mix comparative output value)
LL.ot
99 (max. value)
00 (min. value)
HH.ot
LH.ot
HL.ot
IL.ot
Display of the max
input value
Display of the min
input value
set up the max
comparative output value
set up the min
comparative output value
Set the comparative
output mode
Default value : 01
Key
set up
completed
Key
set up
completed
Key
set up
completed
Key
set up
completed
Key
set up
completed
Key
set up
completed
Key - keep pushing the button(min 2 sec)
Key
Key
set up start
Key
set up start
Key
set up start
Default value :
Default value :
Set value :
Set value :
Set value :
Set value :
Set value :
Set value :
Key
set up
Key로
설정값 변경
Key로
설정값 변경
Key
set up
OFF
ON
Key
set up
completed
Key
set up
completed
※ every parameter set up is not available when the on.
▒ How to change the parameter set value
Key - keep pushing the button(min 2 sec)
Key
Key
set up start
Key
set up start
Key
set up start
Default value :
Default value :
Set value :
Set value :
Set value :
Set value :
Set value :
Set value :
Key
set up
Key로
설정값 변경
Key로
설정값 변경
Key
set up
OFF
ON
Key
set up
completed
Key
set up
completed
1. Pressing key more than 2 sec within the RUN MODE will enter into the Parameter 1 and
pressing key less than 2 sec will enter into the parameter 2.
2. Able to select the parameter by pressing , key and within the selected parameter,
parameter and set value repeatedly flickers in the display unit.
3. Able to change the set value by pressing the key and at this moment, set value flickers
in the display unit(when set value is 0, only the 0th digit of constant value flickers and displayed)
When changing the setting of constant value, able to perform the position shifting by using key.
Example)
When set value is constant, only 0th digit of the constant value will flicker in the display unit.
In order to change the value on 100th digit, press the key 3 times. Each time when users press
the key, position of the digit will shirt to the left and selected digit will flicker in the display unit.
When setting is completed, return to the parameter mode by pressing the key. At this moment,
flickers the parameter and set value repeatedly. Able to return to the RUN mode by pressing the
key again.
Error display code
Initializing set value
Push the button sequancely with pushing the .
And then is displayed. When displaying , push again the button and the all
default value is initialized.
(* Initializing set value is not available when on.)
: Displayed when measuring input electrical pressure ecxeeds max input range.
: Displayed when measuring input electrical volatge ecxeeds max input range.
: Displayed when high comparative output set value is lower than low
comparative output set value.
▒ Retransmission output regarding the power factor display
▒ Retransmission fucntion (Auxiliary Output)
● Current output
Generate 4 - 20 mA d.c for a present displayed value (resolving power 2000)
● Relay output (250 V a.c 5 A below) 1a × 3
※ Caution) PF3 is a power factor meter based on the cycle measurement method.
It might be possible to be late input(max 2 sec) or not accurate when use in
below 5% of the rated voltage.