Please read the safety information carefully then use the product correctly.
The alerts declared in the manual are classified into
Danger
,
Warning
and
Caution
according to their importance
▍Safety information
▍Specification
▍Dimension
DANGER
Warning
Caution
•Users must attach the safety device twice when using the product with the machines which may cause casualties, mass
damage to the assets or etc since it is not designed as the safety device.
•Please supply in the proper power supply voltage accordance to the rating in order to prevent the product from
breaking down or damage.
•Please detach the device after turning off the power. Not doing so may cause an electric shock, malfunction or
breaking the device
•Do not disassemble, manufacture, upgrade or fix the product. There are possibilities of malfunction or electric shock or
fire to occur.
•Please do not use auto-trans in order to maintain the safety of power supply voltage of the product.
Please use the insulation trans.
•When extending the cable, please use thick wire (at least thickness 0.3 ㎟) and at this moment, please watch out for the voltage-drop
•Please separately wire the high-tension wire/power line from the sensor.
•Turning the power ON/OFF continuously will shorten the life expectancy of the product or may cause the malfunction
so please be cautious
•When cleaning the lens and the case, please use a dry cloth and gently wipe the surface. You must not use solvents
such as thinner or alcohol.
•When setting the sensitivity, do not actuate the sensitivity volume with the strong force on it. Doing so may break the volume.
•When using the power supply device (SMPS), users must earth the frame ground (F.G) terminal.
Not doing so may cause malfunction due to the switching noise of the power so please be cautious
• The input/output terminals are subject to electric shock risk.
Never let the input/output terminals come in contact with your body or conductive substances.
28, Gilpa-ro 71beon-gil,
Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hynux.com
HANYOUNGNUXCO.,LTD
Photo Sensor
PEN
series
Thank you for purchasing Hanyoung Nux products.
Please read the instruction manual
carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can see it any time.
MK1501KE190905
INSTRUCTION MANUAL
Cautious 1) the sensing distance can be varied depending on the size, surface condition, glossy, non-glossy of the sensing object.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage
Frame
Power
Supply
(SMPS)
C(0.01㎌-0.1㎌/500 V)
- Noise Eliminating
Condenser
Photo
Sensor
※Users must follow the safety information stated above to avoid product failure.
Model
Power built-in type
PEN-T10A
PEN-M5A
PEN-R700A
Detection method
Through - beam
Retro - reflective
Diffuse - reflective
Detection range
10 m
0.1 ~ 5 m
700 ㎜
Sensing object
Opaque object above Ø20 ㎜ Opaque object above Ø60 ㎜ White non-glossy paper 200 × 200 ㎜
Power supply voltage
24 - 240 VDC/AC (Dual usage) ±10 % 50/60 ㎐
Power
consumption
(current)
transmitter
1 W max
2 W max
receiver
2 W max
Operation mode
Light ON / Dark ON ※ selected by the mode volume
Sensitivity adjustment
-
Built-in the sensitivity adjustment volume
Control output
Relay contact output (1c) 30 VDC 5 A / 250 VAC 5 A (resistive load)
Electrical life expectancy : min 100,000 times
Response time
20 ㎳ max
Hysteresis
-
Within the 20 % of the detection range
Light source
Infrared ray LED (850 ㎚)
Indicator
Output indication : Red LED (In case of the transmitter, red indicates the power state), Stability: Green LED
Ambient illumination
Sunlight : 11,000 Lux max, Incandescent lamp : 3,000 Lux max
Ambient temperature
During operation : -20 ~ 60 C, During storage : -25 ~ 70 C (Without condensation))
Ambient humidity
35 ~ 85 % R.H. (Without condensation))
Degree of protection
IP 64 (IEC)
Insulation resistance
20 ㏁ min (500 VDC mega between the recharging part and case)
Dielectric strength
1,500 VAC (50/60 ㎐ 1 minute)
Vibration resistance
10 – 55 ㎐ 1.5 ㎜ double amplitude for 2 hours each in X, Y and Z directions (but when power is OFF)
Shock resistance
500 ㎨ (Approx. 50 G), 3 times each in X, Y and Z directions
Connection method
Cable extended type (# of cables : 5P, diameter : Ø 6 ㎜, length : 2 ㎜) ※ but transmitter is 2P
Material
Case : heat resistant ABS, Lens: PC
weight(g)
150
■ Outer dimension
■ Reflector (HY-M5)
■ Bracket mounted
▍Connection diagram
■ Through-beam type is limited to the receiver
Int
ernal cir
cuit
BLACK - N.O
WHITE - COM
GRAY - N.C
RELAY
Power supply
Circuit
24 - 240 V DC/AC
BROWN
BLUE
▍Output operation characteristic
Output Indicator
(Red)
Control output
(RELAY/TR)
stability Indicator
(Green)
LIGHT.ON operation
DARK. ON operation
Output Indicator
(Red)
Control output
(RELAY/TR)
stability Indicator
(Green)
▍Installation
■ Through-beam type
■ Retro-reflective type
NO
Method
Picture
Output mode
1
Supply in the power after placing the transmitter
and receiver face to face each other.
Dark ON
fixed
2
Fix either the transmitter or receiver and check for the
range where the operation indicator becomes turned
ON or turned OFF by controlling in the direction of up,
down, left and right. After finishing the confirmation,
place it in the middle and fix it.
3
Place the sensing object within the setting range and
confirm the condition of proper operation.
NO
Method
Picture
Output mode
1
Supply in the power after placing the sensor and
mirror face to face each other in the straight line.
Dark ON
2
Fix either the sensor or mirror and check for the range
where the operation indicator becomes turned OFF by
controlling in the direction of up, down, left and right.
After finishing the confirmation, place it in the middle
and fix it.
3
Place the sensing object within the setting range and
confirm the condition of proper operation and once
the confirmation is finished, fix the sensor.
transmitter receiver
transmitter
Max Sensitivit Volume
Sensor
REFLECTOR
transmitter
REFLECTOR
Sensing object
Sensor
Sensing object
Sensor
receiver
transmitter
REFLECTOR
transmitter
Sensing object
Sensor
transmitter receiver
transmitter
Max Sensitivit Volume
Sensor
REFLECTOR
transmitter
REFLECTOR
Sensing object
Sensor
Sensing object
Sensor
receiver
transmitter
REFLECTOR
transmitter
Sensing object
Sensor
■ Diffuse-reflective type
NO
Method
Picture
Sensitivity Volume
Output mode
1
After removing the sensing object, turn sensitivity
volume gradually to the max direction and once
indicator lights up, that position will be referred as ‘A’.
(If indicator does not get turned ON (OFF) even in the
position of maximum set on the max position.)
Light ON
2
Place the sensing object in the desirable setting position
and gradually turn the sensitivity volume from ‘A’ to the
‘min’ direction and once the indicator gets to turned
ON (OFF) than that position will be referred as ‘B’.
3
Place the sensitivity volume in the middle of max
and ‘A’ or ‘B’ and confirm the operation condition of
sensing object that occurs within the setting range.
transmitter receiver
transmitter
Max Sensitivit Volume
Sensor
REFLECTOR
transmitter
REFLECTOR
Sensing object
Sensor
Sensing object
Sensor
receiver
transmitter
REFLECTOR
transmitter
Sensing object
Sensor