HANYOUNG NUX MC9 Series Manual Download Page 12

21

2 0

§ „”—‰ˆ£

(TD : Derivative Time)

Initial Value 

: 60 sec. 

Setting range

: 1 ~ 3600 sec.  

Contents

: Set Derivative operation time .

If you operates AT, it is set automatically.

C H

ZO N E

P V

S V

§ ”æ•

˚

·º

(PB : Pro portional Band)

ON/OFF 

 

 If 

 it 

 set 

 as 

 PB=0, 

 operate 

 ON/OFF 

 control.

§ TI : Integral Time

Initial Value 

: 60 sec. 

Setting range

: 1 ~ 3600 sec.  

Contents

: Contents: Set Integral operation time..

If you operates AT, it is set automatically.

C H

ZO N E

P V

S V

Initial Value : 

30 

¡ , 30.0 ¡ , Voltage input : 3.0 % 

Setting range

: 0(0.0) ~ •„

˛

`

ˆ·º“

Contents

: Set PB to control P, PI, PD & PID.

If you operates AT, it is set automatically.

C H

ZO N E

P V

S V

§ LBD : Control Loop Break Alarm Deadband

§ AL 1 : Alarm 1

§ AL 2 : Alarm 2

Initial Value : 

Voltage input : 0 ¡ , 0.0 ¡

Setting range

: 0 ~ 100 sec

Contents

: Contents: Set all extents except the range

of errors occurred. Displayed in case only 
LBA is set in alarm 1. Not operated if LBA
setting value is set as 

¡ 0¡–

.)

C H

ZO N E

P V

S V

Initial Value : 

Maximum value of range

(Refer to Input type & Range code)

Setting range

: Range(Refer to Input type & Range code)  

Contents

: Set the setting value of Alarm 1.  

Displayed in case only LBA is set in
alarm 1. Not displayed if alarm type is 
FAIL or LBA(HBA).

C H

ZO N E

P V

S V

Initial Value : 

Maximum value of range

(Refer to Input type & Range code)

Setting range

: Range(Refer to Input type & Range code)  

Contents

: Set the setting value of Alarm 2.  

Displayed in case only LBA is set in
alarm 2. Not displayed if alarm type is 
FAIL or LBA(HBA).

C H

ZO N E

P V

S V

§ AL 3 : Alarm 3

Initial Value : 

Maximum value of range

(Refer to Input type & Range code)

Setting range

: Range(Refer to Input type & Range code)  

Contents

: Set the setting value of Alarm 3.  

Displayed in case only LBA is set in
alarm 3. Not displayed if alarm type is 
FAIL or LBA(HBA).

C H

ZO N E

P V

S V

Summary of Contents for MC9 Series

Page 1: ...n ng g H HA AN NY YO OU UN NG G p pr ro od du uc ct t P Pl le ea as se e r re ea ad d t th hi is s m ma an nu ua al l c ca ar re ef fu ul ll ly y a an nd d k ke ee ep p t th hi is s f fo or r f fu ut...

Page 2: ...guarantee or suitabilityfor a certain purpose and it does not off er any guarantee for those that do not limit this matt e r Every programs contained in this product is protected by copyright Without...

Page 3: ...k p pa ac ck ki in ng g c co on nt te en nt ts s 2 1 1 Check contents 1 2 Safe ty Information 2 1 Suffix Code 2 2 Input Type Range Code 2 3 Rating 2 4 Dimentions Panel Cutout 2 5 Terminal Arrangement...

Page 4: ...Please make this manual to be delivered to the final user and to be placed where can be found and seen easily Please install and operate this product after reading this manual carefully This manual co...

Page 5: ...e o of f 8 8 c ch ha an nn ne el ls s 6 M O D E L MC9 4 Control Direction Input Output1 4 Heating Output Output 5 8 Cooling Output IN case of D R N is fixed IN case of W choose among M S T 4 5 Option...

Page 6: ...5 Direct Contro l Down scale Reverse Contro l Up scale On Off P PI PD PID Contro l Direct Control Reverse Contro l On less than 2 Off over 15 Relay Output 250 V a c 3A Resistive Load Proportional Time...

Page 7: ...Method Others O peration Condition Alarm 1 2 3 250 V a c 1 A Resistive Load HBA Current Tr ansformeter CT 0 100 A J D ELETRONIC Co Ltd Extent 5 of span or 2 A Bigger side Measure terminal Power termin...

Page 8: ...e Detector T C Thermocouple V d c Power Voltage Channel 7 RTD Resistance Te m perature Detector T C Thermocouple V d c Power Voltage Channel 8 RTD Resistance Te m perature Detector T C Thermocouple V...

Page 9: ...nitor Displays Parameter Channel for setting currently Lights Lamp when Output 1 8 is on Flickers Lamp when the displayed channel is in AT currently Monitor screen Displays the number of controlling Z...

Page 10: ...r Range Initial Value Signal S V ZO N E H B C LBA LBD AL1 AL2 AL3 P B T I T D A R RATE DISL C H E N AT H B A BIAS FR H FR L ALT1 ALT2 ALT3 FILT CT ADDR PSL BPS PRI STP DLN R PT S CA N LOC1 LO C 2 N a...

Page 11: ...and control direction is direct If PV value is not rising over 2C 2F 2 within setting time in LBA it happens In case output is 0 and control direction is reverse If PV value is not falling over 2C 2F...

Page 12: ...rors occurred Displayed in case only LBA is set in alarm 1 Not operated if LBA setting value is set as 0 C H ZO N E P V S V Initial Value Maximum value of range Refer to Input type Range code Setting...

Page 13: ...neously When you operates AT in a channel only AT is On after you choose channel by pressing CH key AT operates in the channel wanted in that time C H ZO N E P V S V Rate SV Rate CHEN Channel Enable A...

Page 14: ...ted in HBC of operation mode Set HBA value as 85 of Current load HBA can fl t be used in case of Current output Set HBA SV a little bit lower when variation of power supply is big Current detection ex...

Page 15: ...n Parameter is displayed C H ZO N E P V S V 26 F i l t e r ADDR Address BPS Bits per Second I n i t i a lvalue OFF Setting range 0 120 s Contents Set the first time of delayed filter to r e m ove any...

Page 16: ...ion Set by using key in sequence of numbers wanted I fyou press button once 0 of the first SV is f l i c kered If you press button again 00 i sf l i c kered and then do once more 0 of 000 i sf l i c k...

Page 17: ...n y yo ou u d de ec cr re ea as se ed d S SV V v va al lu ue e C Ch ha an ng gi in ng g 4 40 00 0 t to o 3 39 90 0 Press key to flicker Number of 10 unit like Figure A twice Press key to change 0 of 1...

Page 18: ...culate the most suitable PID and LBA value automatically and set yp PID and LBA value into each parameter STA RT Auto Tuning U Please select all parameters except for PID LBA U Lock level 1 Lock level...

Page 19: ...100 EU 0 100 I fyou select in Alarm No 15 in ALT1 LBA Alarm will operate If you select in Alarm No 15 in ALT2 3 HBA alarm will operate HBA alarm could be operated only in case output type is RELAY or...

Page 20: ...PV SV ALM ON OFF ON PV No Waiting operation deviation Low SV alarm High SV alarm High temp Low temp SV ON OFF High temp Low temp ON OFF SV 36 High deviation alarm Alarm operation High Low deviation a...

Page 21: ...falling over 2C 2F 2 within setting time in LBA it happens In case output is 100 and control direction is direc t If PV value is not falling over 2C 2F 2 within setting time in LBA it happens In case...

Page 22: ...parameter setting of contro l I fcontact input status is RUN mode RUN STOP is selected by key contro l RUN contact is closed RUN STOP contact is opened RUN STOP by contact input RU N STO P Section RUN...

Page 23: ...e Power voltage Input Type Sampling time N u m ber of channel Input resolution Input impedance Tolerable signal resistance Tolerable wiring resistance Tolerable input voltage Standard junction temp c...

Page 24: ...ue Output status Direct 100 Reverse 0 PV status less than Direct 0 over Reverse 100 Measure POWER OFF ON If it is not returned to normal please contact our agent in near or speak to a customer service...

Reviews: