Chapter 3 Installation
50
Connecting the emergency stop button
It is recommended that you connect one or more emergency stop button. The
emergency stop button is composed as follows.
Safety protection stop and restart
As an example of basic safety protection device, basically, when the door opens, you
can press the door switch to stop the robot. You can configure the function as follows.
If you cannot close the door after a worker passed through it, then you can use the
following features. As another way to resume robot operation, you can use the safety
mat or the safety class laser scanner.