INS_TER-F01[PD]
08/12/19
PAGE 2
INSTALLATION AND OPERATION MANUAL
TER-F01 SERIES
FIGURE 1 – TER-F01[PD] EXTENDER
ETHERNET
ETHERNET
Power: Supplied by PSE
Power Consumption: <1 W
FIGURE 3 – INDICATING LEDS
COPPER
GREEN
Solid – No Activity
Blinking – Activity
YELLOW
Highest Data Rate
(100Mb)
INSTALLATION CONSIDERATIONS
The TER-F01[PD] is supplied as a 3.3 × 1.25 × 1.25 in (8.4 × 3.2 × 3.2 cm) tube
module.
Units should be installed in dry locations protected from extremes of temperature
and humidity.
WARNING
: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient
- If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (T
ma
) specified by the manufacturer.
B) Reduced Air Flow
- Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not
compromised.
FIGURE 4 - DIMENSIONS
Dimensions are for a tube module
3.2 cm
[1.25 in]
3.2 cm
[1.25 in]
8.4 cm
[3.3 in]
Note: Ports are universal, and either can be used as in or out.