Hanwei GD Series Operation Manual Download Page 5

Hanwei Electronics Co., Ltd                                                                www.hwsensor.com

 

[email protected]                              Fax: 86-371-67169090      Tel: 86-37167169070/80

 

5 Using Instructions: 

5.1 GD401 /GD601 

5.1.1. Plug in, (If ventilate fan, electro valve or other equipment is need to be connected, 

please  connect  corresponding  circuit  firstly.),  then  the  green  POWER  light  and  yellow 

W-UP light will be on. The appliance assumes non-operating status for three minutes while 

the sensor warms up. After warm up, the yellow W-UP light will be off automatically and the 

appliance enters detecting status. 

 

5.1.2. If the gas in the environment rises above the preset alarm level, the appliance will 

enter alarm status, the red ALARM light will shine and the buzzer will give sound alarming. 

Meanwhile, the alarm will activate the relay or the valve output; at the same time, please 
cut off gas supply promptly and open the window. Don’t try to switch on or off any electric 

appliance,  including  mobile  phone  and  such  communications  tools.  Ask  professional 

person to eliminate the gas leaking malfunction quickly (the alarm with function of gas shut 

off valve shall output one close pulse signal each 10 seconds) 

 

5.1.3.  Once  the  gas  concentration  around  drop  under  the  preset  alarming  level,  the 

detector will stop alarming automatically and the ventilating fan will also stop automatically. 

The detector gets into detecting state again. 

 

5.1.4.  If  the  yellow  fault  alarm  light  is  on,  it  shows  there  is  something  wrong  with  the 
detector and the detector can’t detect gas. Then please contact the distributor. 
 

5.1.2 Button operation: 

W-UP: press this button to stop the warm up and the detector get into detecting state 

immediately. 

Test  button:  The  appliance  will  simulate  alarming  by  pressing  test  button  under 

detecting status. 

Once the gas concentration around drop under the preset alarming level, the detector will 

stop  alarming  automatically  and  the  ventilating  fan  will  also  stop  automatically.  The 

detector gets into detecting state again. 

 

6 Troubleshooting Guide 

Problems… 

Maybe caused by… 

Solution 

Green POWER light   

is off

 

Plug in not correct   

Plug in again   

light broken 

Contact the distributor   

Press test button 

without alarm sound 

Circuit fault 

Contact the distributor 

Can’t detect the gas 

The preheat is not finished 

Wait until the preheat 

finish 

Summary of Contents for GD Series

Page 1: ...GD Series Gas Alarm Operation Manual Hanwei Electronics Co Ltd...

Page 2: ...factured with advanced technology It provides visual and audible signals when the gas concentration reaches the presetting range and reminds you to take prompt favorable action 2 Specifications Model...

Page 3: ...ded Near the windows or passage with strong wind Water fog and drop or such moist place Easy polluted or high tem environment near Oven Covered by other things 4 3 Choosing a proper installation way p...

Page 4: ...9070 80 3 Installation 2 Choose a suitable wall or place per the above 4 1 4 2 requests Fix a nail size 2 into the wall Hang the appliance on the nail with the hanging hole as the drawing below 4 4 Co...

Page 5: ...he alarm with function of gas shut off valve shall output one close pulse signal each 10 seconds 5 1 3 Once the gas concentration around drop under the preset alarming level the detector will stop ala...

Page 6: ...alarm frequently to keep air vent freely and the lights clear 7 5 The detector needs to be keeping power on for more than 24 hours after a long time delivery of storage 8 Gas Safety Knowledge 8 1 Sort...

Page 7: ...Other reasons 8 5 Solutions of gas leakage Put out the fire Shut off the gas valve Open the windows and doors Check the leakage source Don t try to turn off any electric equipment when alarming contin...

Page 8: ...HANWEI ELECTRONICS CO LTD No 169 Xue Song Road National Hi Tech Zone Zhengzhou 450001 Henan China Phone 86 371 67169070 67169080 Fax 86 371 67169090 E mail sales hwsensor com Website www hwsensor com...