background image

Logic Analyzer 

                 Hantek4032L

 

 

Chapter 5 Trigger 

This chapter focuses on the following topics:   

‹

  Base Trigger Setup 

‹

  Advance Trigger Setup 

‹

 Immediately 

Trigger 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User’s Manual                                                                                                                              30 

Summary of Contents for 4032L

Page 1: ...User s Guide Hantek4032L PC USB Logic Analyzer www hantek com ...

Page 2: ... 3 Setup 14 2 4 Analyzer 14 2 5 Help 15 Chapter 3 Advanced 16 3 1 Control Panel 17 3 2 Bus Panel 18 3 3 Waveform Panel 20 3 4 Measurement Panel 22 3 5 Export Data 23 Chapter 4 Bus Plug in 24 4 1 Summary 25 4 2 Example 27 Chapter 5 Trigger 30 5 1 Base Trigger Setup 31 5 2 Advance Trigger Setup 33 5 3 Immediately Trigger 33 Appendix 34 Hardware Specification 35 Channels 36 Block Diagram 37 Cleaning ...

Page 3: ...connection the import or export of products before the end be sure to correct grounding for this product Properly connected probe Probe the ground with the same potential Do not connect high voltage ground See all the terminals rating To avoid excessive current fire and the impact see the product of all the ratings and tags please connect products in the product manual inspection prior to understa...

Page 4: ... in some way of capturing narrow pulse interference It has the feature of delayed ability to capture the required observation points around the waveform in a variety of digital information capture function The Hantek4032L has intuitive and flexible displays to facilitate dynamic analysis can transform the information and the user can use the binary decimal hexadecimal or ASCII that information to ...

Page 5: ...Logic Analyzer Hantek4032L Chapter 1 Getting started This chapter focuses on the following topics System Requirements Installing Software Installing Driver User Interface User s Manual 3 ...

Page 6: ...antek4032L 1 1 System Requirements Minimum System Requirements Operating System Windows XP Vista Win 7 Memory 128MB Graphic Card Microsoft DirectX supported Screen resolution 1024x768 Color depth 16bit User s Manual 4 ...

Page 7: ...tion CD into the CD ROM drive 2 The installation should start up automatically Otherwise in Windows Explorer switch to the CD ROM drive and run Setup exe 3 The Hantek4032L Installation is started Click Next to continue 4 Choose a destination directory Click Next to continue User s Manual 5 ...

Page 8: ...Logic Analyzer Hantek4032L 5 Check the setup information Click Next to start copying of files 6 This status dialog is displayed during copying of files User s Manual 6 ...

Page 9: ...Logic Analyzer Hantek4032L 7 Updating Your System Configuration 8 The installation is complete User s Manual 7 ...

Page 10: ...r 1 Connect the A Type Plug of USB cable to your PC s USB port 2 Connect the B Type Plug of USB cable to Hantek4032L s USB port 3 New hardware is found 4 New hardware search wizard starts 5 New hardware search wizard starts to search User s Manual 8 ...

Page 11: ...Logic Analyzer Hantek4032L 6 New hardware wizard installs software User s Manual 9 ...

Page 12: ...he Hantek4032L or you may lose data and or your ability to communicate with the device If the LED is illuminated but then turns off the computer has lost communication with the Hantek4032L To restore communication disconnect the USB cable from the computer and then reconnect is This should restore communication and the LED should turn back on User s Manual 10 ...

Page 13: ...rface Hantek4032L provides users with a simple and full featured interface so that users needn t spend a lot of time to learn At the same time it provides control panel waveform panel bus panel measurement panel trigger panel User s Manual 11 ...

Page 14: ...Logic Analyzer Hantek4032L Chapter 2 Menu This chapter focuses on the following topics File View Setup Analyzer Help User s Manual 12 ...

Page 15: ...z Print Preview Preview the current waveform z Pint Setup Setup print type z Exit Exit Hantek4032L 2 2 View z Toolbar Show or hide the toolbar window z Status Bar Show or hide the status window z Control Window Show or hide the control window z Measure Window Show or hide the measure window z Zoom In Enlargement waveform view z Zoom Out Reduction waveform view z Zoom All Show entire waveform view ...

Page 16: ...ses the waveform view to roll to the first sample position z Scroll to Trigger Causes the waveform view to roll to trigger position z Scroll to Last Sample Causes the waveform view to roll to the last sample position z New Mark Create a new Mark z New Measurement Create a new measurement z Zoom In Enlargement waveform view z Zoom Out Reduction waveform view z Zoom All Show entire waveform view Use...

Page 17: ...Logic Analyzer Hantek4032L 2 5 Help z Help Content Open the User Manual z About Show the copyright of the device User s Manual 15 ...

Page 18: ...Logic Analyzer Hantek4032L Chapter 3 Advanced This chapter focuses on the following topics Control Panel Bus Panel Waveform Panel Measurement Panel Export Data User s Manual 16 ...

Page 19: ...the sample rate from 1MS s to 400MS s Sample Depth User can set the sample depth 1k 2k 10k z Threshold Configure the input trigger level z Trigger Trigger Condition Popup the trigger setup dialog Force Trigger Trigger immediately once Stop Stop trigger Single Trigger under the trigger condition once User s Manual 17 ...

Page 20: ...s of them to some bus The list box contains all of the bus you can add or delete the bus For example Assign a bus My Bus which has 7 signals A0 A1 A2 A3 A4 A5 and A6 1 Click the button Add Then a new bus is added to the list 2 Click the pane under the A0 A1 A2 A3 A4 A5 and A6 If the pane is filled of red it means you have add the signal to the bus User s Manual 18 ...

Page 21: ...ntek4032L 3 Double click the name of the bus which is NewBus1 in this example Then popup an edit box in which you can input the bus name My Bus 4 Then Click OK the My bus has been added to the waveform User s Manual 19 ...

Page 22: ...u can observe the waveform by the waveform panel in the main window The list contains all of the bus in bus panel in the left part of the waveform panel Click the name of the bus with the right mouse button you can configure the bus User s Manual 20 ...

Page 23: ...in the list 3 Display Style You can set the display style of the bus in the waveform Analog or Digital 4 Color You can modify the color of the bus displayed in the waveform 5 Show Property Open the bus setup panel Click the waveform with the right mouse button the waveform help menu popup You can operate the Hantek4032L by the menu User s Manual 21 ...

Page 24: ...ew measurement to the list in the measurement panel Select the Measure combo box You can modify the types of measurement There are 4 types for you such as Interval rate transitions and cycles Click the Delete you can delete the measurement item selected in the list Click the Show Property you can modify the measurement Also you can click the main menu Analyzer New Mark to add new mark for measurem...

Page 25: ...Logic Analyzer Hantek4032L 3 5 Export Data Click the menu File you can export the data to file If you select the CSV file you will export the data as the following User s Manual 23 ...

Page 26: ...Logic Analyzer Hantek4032L Chapter 4 Bus Plug in This chapter focuses on the following topics Summary Example User s Manual 24 ...

Page 27: ...1 Summary Click right mouse select Bus Plug in I2C The list box contains all of the plugs installed in your computer You can add them to waveform by checking them User can modify the property of the plug in the box User s Manual 25 ...

Page 28: ...Logic Analyzer Hantek4032L User s Manual 26 ...

Page 29: ...lyze the I2 C bus you should go with the steps following 1 Click menu Setup Bus Setup or toolbar open the bus setup dialog 2 Open the plug manager and the I2 C setup dialog Click right mouse and select Bus Plug in I2C to open the setup dialog User s Manual 27 ...

Page 30: ...Logic Analyzer Hantek4032L 3 Click menu Setup Trigger Setup or toolbar open the bus setup dialog do these steps 4 Then you can see the following User s Manual 28 ...

Page 31: ...ou can see the stable and sensitive I2C signals If there is measuring instrument line interference user can adjust the trigger voltage value Set initial trigger voltage value for SCL and SDA is 1 5V try to adjust the value to obtain the stable signal User s Manual 29 ...

Page 32: ...Logic Analyzer Hantek4032L Chapter 5 Trigger This chapter focuses on the following topics Base Trigger Setup Advance Trigger Setup Immediately Trigger User s Manual 30 ...

Page 33: ...a Data value delay Data and edge 1 Rising edge Select the Rising edge in the tree select the signal in the combo box Then it will triggered by a rising edge appeared on the selected signal 2 Falling edge Trigger by a falling edge appeared on the selected signal 3 Rising or falling edge Trigger by a rising or falling edge appeared on the selected signal 4 Data Trigger at the appearance of a specifi...

Page 34: ...lue delay Trigger at x time after the appearance of a specified value 6 Data and edge Trigger at the appearance of a specified value on the selected bus and rising falling or rising or falling edge of the selected signal User s Manual 32 ...

Page 35: ...e the advance trigger There are two trigger conditions trigger A and trigger B You can set the trigger mode by clicking the Trigger Mode group box There are four parts in each condition Data Duration Edge and Relative trigger value 5 3 Immediately Trigger Click Setup Trigger Setup and select Immediately Immediately Triggered immediately after the sampling starts User s Manual 33 ...

Page 36: ...Logic Analyzer Hantek4032L Appendix Hardware specification Input connector pin assignments Block Diagram Cleaning and Maintenance User s Manual 34 ...

Page 37: ...gnal bandwidth 150 MHz Min time resolution 2 5ns Sample Depth 64M Buffer Depth 2G Trigger s Max rate 200 MHz Compatible input TTL LVTTL CMOS LVCOMS ECL PEC L EIA Electrostatic Protected 15KV Power Adapter 5V Temperature range 10 60 Dimension Length 105mm Width 80mm Height 25mm Weight 0 38Kg Accessories A USB cable A set Little Test Hook A Power Adapt A Logic Analyzer Cable A CD User s Manual 35 ...

Page 38: ...y 9 A5 Grey 10 A6 Grey 11 A7 Grey 12 A8 Grey 13 A9 Grey 14 A10 Grey 15 A11 Grey 16 A12 Grey 17 A13 Grey 18 A14 Grey 19 A15 Grey 20 AST0 Grey Level B Pin Number Wire ID Wire Color 1 Ground Black 2 BCLK Grey 3 Ground Black 4 B0 Grey 5 B1 Grey 6 B2 Grey 7 B3 Grey 8 B4 Grey 9 B5 Grey 10 B6 Grey 11 B7 Grey 12 B8 Grey 13 B9 Grey 14 B10 Grey 15 B11 Grey User s Manual 36 ...

Page 39: ...Logic Analyzer Hantek4032L 16 B12 Grey 17 B13 Grey 18 B14 Grey 19 B15 Grey 20 AST1 Grey Block Diagram User s Manual 37 ...

Page 40: ...ters 1 Use velvet cloth contact the surface of the equipment 2 Pease do not use any corrosive or chemistry Caution Please make sure the equipment is dry enough before going to work Avoid mangling the equipment or hurting body because of water Maintenance Don t put the equipment under the sun for a long time Put it in wind to the best of one s abilities Caution In order to not mangle the equipment ...

Reviews: