CONNECTING THE SC-20 SPEED CONTROLLER

With the motor in place you can connect the SC-20 speed controller. Do not connect any 
power before the motor is connected to SC-20. Take the motor external power cable and 
connect it to the provided slot on the rear of SC-20. 
Now plug it into your AC wall outlet for operation.

SPEED AUJUSTMENT USING TH GRS METER & SC-20

T-20 is equipped with a GRS meter (PictureA) and SC-20 speed controller.
Both can be used in conjunction to calibrate the speed of motor to an accurate setting for 
both 33.3rpm and 45rpm playback. Press the power “ON” of the SC-20 and then select 
33.3rpm or 45rpm for operation. Next switch “ON” the motor housing and the platter will 
begin to rotate slowly. Please allow the platter to rotate for 2-3 minutes before checking 
the speed. 

After the platter has been rotating for few minutes you may check the speed of the 
platter by pressing the button located on the plinth which is next to the display to 
activate the digital read out of the speed of the platter. After several seconds you will see 
the correct speed on the display. If you find the speed is a bit slow or fast you may adjust 
the speed by using the rotary on the SC-20 under each speed indicated. After each 
adjustments please check the display for the new speed. Once you have worked on 
getting the correct speed as possible. You may turn off the display by pressing down the 
button next to the display to turn off the display. 

Summary of Contents for T-20

Page 1: ...T 20 TURNTABLE USER MANUAL...

Page 2: ...se read the following manual carefully and in detail before beginning the setup 1 2 3 4 7 8 5 6 9 11 10 Chassis Synchronized Motor Record Clamp Silicon Belts Bubble Level Meter Bearing Housing Strobos...

Page 3: ...VTA Magnetic Suspension Low Friction Bearing Anodized aluminum Platter Anti resonance and damping acrylic aluminum sandwich SC 20 33 3rpm Adjustable 45rpm Adjustable Magnetic Suspension Feet ON OFF 33...

Page 4: ...to ensure accurate operation Please do not do the followings 1 Do not remove the reflective tape on the bottom of the platter otherwise the GRS meter will not operate 2 Do not use the SC 20 for opera...

Page 5: ...e packaging and locate the small battery compartment under the chassis Unscrew and plug in the 9V battery Leveling the turntable to match your rack Place the turntable on a stable surface along with t...

Page 6: ...of the motor housing LEVELING THE TURNTABLE It is very important to level the turntable before any adjustments Therefore please position the T 20 on a stable surface which would be suitable for the op...

Page 7: ...for operation Next switch ON the motor housing and the platter will begin to rotate slowly Please allow the platter to rotate for 2 3 minutes before checking the speed After the platter has been rotat...

Page 8: ...0mm x 128mm 16 2 KGS LIMITED WARRANTY HANSS ACOUTSICS warrants the product designated herein to be free from manufacturing defects provided proper operation for a period of two years from the original...

Reviews: