7. Maintenance

Cleaning

After using, please clean the device with wet towels.  Please be sure that the power is switched off when 

you clean it and all dmx and power cables are plugged out. 

Do not use solvents or abrasives for cleaning. Just wet towel is enough for cleaning.

Keep all power sockets or contacts always clean and dry.

Especially, lots of carbon remnant or soot can be accumulated on the electric spark pins. 
Clean them with soft-brush. Do not bend spark pins or change the gap between arc pins.

Leaking Test

Before using, always check any leaking from the device.

A regular leaking test must be made every six months at 18 bar longer than 20 minutes.

Filter

The filter is built in the device to prevent foreign objects or dusts from being jammed in the fuel line 

from fuel reservoir to pump and solenoid valve. If some dusts or foreign objects are jammed in this filter, 

the filter needs to be cleaned. If not,  the flame height will be seriously lowered.  In this case, please 

refer to How to clean the filter of our repair service manual which is provided separately.

Damages caused by misusage and maloperation, etc

The devices have been designed to generate flame effects. Discuss all other applications with the 

manufacturer before usage. In the case that one of the events stated above has happened we are only 

liable if the defect was within our range of influence. 

Especially the user's work must comply with the safety regulations and the instructions given in this 

manual at all times.

High Voltage

For the electrical ignition of the fuel very high voltages that can be dangerous to life are generated in the 

device. Never operate the device if the cap of fuel reservoir is not tightly closed. Furthermore never 

touch anything inside the device and never touch the ignition electrodes while the device is switched on.

Warranty

The warranty period is 12 months.

If there is any defect during in this period please pack the device properly and send it to the 

manufacturer with carriage paid to have it repaired free of charge. Please do not forget to attach a 

description of the symptoms, which have occurred. Warranty is excluded if the device was damaged due 

to wrong usage or excessive stress.

Summary of Contents for Hurricane-AW

Page 1: ...Hurricane AW Manual v1 1 2021 Distributed by Hansol Global Corporation 43 4 Sicheongro 677beongil Paltan myeon Hwasung si Gyeonggi do S Korea www colorfirefly com diotima1201 gmail com 0 Hurricane AW...

Page 2: ...n and then touch it 9 Inspect thoroughly and regularly the devices every 6 months for reliability 10 Do not use damaged equipment If a damage is found immediately repair the device or if you can t rep...

Page 3: ...d with dmx controller 2 2 Features All in one flame system without any external pressure propelling media and fuel reservoir 2 small pressure pumps are built in the device Max 11L fuel reservoir and a...

Page 4: ...be used The pumps will be broken Fuel consumption 200ml sec Fuel Tank Capacity 11 Liter 3 17gallon Fuel reservoir is built in the device Moving range 0 180 Moving Speed 18ms from 0 to 180 Propelling...

Page 5: ...l reservoir from accumulator Before the pump working close this VALVE to get the working pressure After the show open this VALVE to remove the pressurized fuel from accumulator pumps and piping When y...

Page 6: ...12 The device has 19 DMX channels The spark ignition CH3 solenoid valve for flame CH2 and Pump CH4 work at the range of dmx key 200 255 At the range of 0 to 199 the ignition the solenoid valve and pum...

Page 7: ...o give you an idea of the labeling Left Middle Right AUDIENCE 4 2 Definition of Positions The spectrum of 180 can be used This spectrum was separated into 9 positions in steps of 22 5 for the control...

Page 8: ...nce is pre programmed on the device Flame shooting time is 20ms 0 2sec See the chart 1 for detail 6 Bank 1 61 255 13 autoshows are pre programmed Each program is selected by DMX key value See the char...

Page 9: ...ower on 4 5 Channel 3 Electric Spark Starting address 2 The third channel starting address 2 activates the electric spark with dmx values 200 and 255 Only after pump starts it can work Without pump st...

Page 10: ...1 4 2 Stepp wave sequences 136 150 1 2 3 4 5 wave from 90 to 180 151 165 5 wave from 0 to 90 4 3 2 1 166 180 1 2 3 4 wave 181 195 4 wave 3 2 1 196 210 1 2 211 225 1 2 Wave sequences 226 240 L R wave...

Page 11: ...16 91 105 L R 1 2 3 4 5 L R 8 7 6 106 120 L R 5 4 3 2 1 L R 6 7 8 121 135 Random 5 3 1 4 2 Stepp wave sequences 136 150 1 2 3 4 5 wave from 90 to 180 151 165 5 wave from 0 to 90 4 3 2 1 166 180 1 2 3...

Page 12: ...ve for remove the pressure inside the pump and pipings Caution Check if there is any fuel leakage from fuel reservoir At the bottom of the device there is a fuel drain bolt Check if any fuel leaks fro...

Page 13: ...o clean the filter of our repair service manual which is provided separately Damages caused by misusage and maloperation etc The devices have been designed to generate flame effects Discuss all other...

Reviews: