Manual v1.1
2021
Distributed by :
Hansol Global Corporation
#43-4 Sicheongro , 677beongil Paltan-myeon Hwasung-si Gyeonggi-do S.
Korea
www.colorfirefly.com
[email protected]
0
Page 1: ...Hurricane AW Manual v1 1 2021 Distributed by Hansol Global Corporation 43 4 Sicheongro 677beongil Paltan myeon Hwasung si Gyeonggi do S Korea www colorfirefly com diotima1201 gmail com 0 Hurricane AW...
Page 2: ...n and then touch it 9 Inspect thoroughly and regularly the devices every 6 months for reliability 10 Do not use damaged equipment If a damage is found immediately repair the device or if you can t rep...
Page 3: ...d with dmx controller 2 2 Features All in one flame system without any external pressure propelling media and fuel reservoir 2 small pressure pumps are built in the device Max 11L fuel reservoir and a...
Page 4: ...be used The pumps will be broken Fuel consumption 200ml sec Fuel Tank Capacity 11 Liter 3 17gallon Fuel reservoir is built in the device Moving range 0 180 Moving Speed 18ms from 0 to 180 Propelling...
Page 5: ...l reservoir from accumulator Before the pump working close this VALVE to get the working pressure After the show open this VALVE to remove the pressurized fuel from accumulator pumps and piping When y...
Page 6: ...12 The device has 19 DMX channels The spark ignition CH3 solenoid valve for flame CH2 and Pump CH4 work at the range of dmx key 200 255 At the range of 0 to 199 the ignition the solenoid valve and pum...
Page 7: ...o give you an idea of the labeling Left Middle Right AUDIENCE 4 2 Definition of Positions The spectrum of 180 can be used This spectrum was separated into 9 positions in steps of 22 5 for the control...
Page 8: ...nce is pre programmed on the device Flame shooting time is 20ms 0 2sec See the chart 1 for detail 6 Bank 1 61 255 13 autoshows are pre programmed Each program is selected by DMX key value See the char...
Page 9: ...ower on 4 5 Channel 3 Electric Spark Starting address 2 The third channel starting address 2 activates the electric spark with dmx values 200 and 255 Only after pump starts it can work Without pump st...
Page 10: ...1 4 2 Stepp wave sequences 136 150 1 2 3 4 5 wave from 90 to 180 151 165 5 wave from 0 to 90 4 3 2 1 166 180 1 2 3 4 wave 181 195 4 wave 3 2 1 196 210 1 2 211 225 1 2 Wave sequences 226 240 L R wave...
Page 11: ...16 91 105 L R 1 2 3 4 5 L R 8 7 6 106 120 L R 5 4 3 2 1 L R 6 7 8 121 135 Random 5 3 1 4 2 Stepp wave sequences 136 150 1 2 3 4 5 wave from 90 to 180 151 165 5 wave from 0 to 90 4 3 2 1 166 180 1 2 3...
Page 12: ...ve for remove the pressure inside the pump and pipings Caution Check if there is any fuel leakage from fuel reservoir At the bottom of the device there is a fuel drain bolt Check if any fuel leaks fro...
Page 13: ...o clean the filter of our repair service manual which is provided separately Damages caused by misusage and maloperation etc The devices have been designed to generate flame effects Discuss all other...