Hansen Radar Outdoor Installation Instructions Download Page 2

Technical modifications reserved. Content is protected by copyright.          August 2021   M06e/08/2021

Radar Outdoor 

Electrical connection

Ÿ

For  trouble-free  operation  the  Radar  Outdoor  require  a 

hansen 

converter  of  the  C100/...  series.  The  Radar  Out-

door must only be operated with a converter of this type.

Ÿ

The Radar Outdoor LEDs are operated in series connection 
(see  connection diagram below). 

Ÿ

Connecting  the  LEDs  in  parallel,  e.g.  to  12  volts,  is  not 
permitted and will destroy the LEDs.

 

Ÿ

The connection of the Radar Outdoor LEDs to the con-
verter  must  only  be  made  when  the  system  is  de-
energized.

 Establish and check the connection between the 

LEDs  and  the  converter  first 

before  switching  on  the 

mains voltage.

Ÿ

The Radar Outdoor LEDs and the converter are connected 
in series as shown in the diagram below:

 

The  POSITIVE  pole  (red  cable)  of  the  converter  is 
connected to the POSITIVE side of the first Radar-LED.

 

The  NEGATIVE  pole  (black  cable)  of  the  converter  is 
connected to the NEGATIVE side of the last Radar-LED.

 

The individual Radar-LEDs are connected to each other 
“POSITIVE to NEGATIVE”.

Ÿ

For the connection to the converter or between the Radar 
Outdoor LEDs we recommend using the WAGO connector 
type 221-412 (article no. 5 0004 013).

Ÿ

When  using  the  converters  C100/990  or  C100/990D,  the 
WAGO  connectors  must  be  protected  with  an  additional 
insulating cap (12 x 30 mm, article no. 5 0004 004).

Ÿ

To  prevent  ingress  of  water  into  the  connector/insulating 
cap, arrange them in such a way that the cables enter the 
connectors  from  below.  This  will  allow  any  developing 
condensate to flow off.

Ÿ

The Radar Outdoor LEDs are operated in series connection 
with a current of 100 mA.

Ÿ

Currents  below  100 mA  are  permitted,  whereas  currents 
above  100 mA  are  not  permitted  as  they  will  damage  the 
LEDs.

Ÿ

The Radar  Outdoor system may only be operated with the 
following 

hansen

  converters  and  the  corresponding 

maximum number of LEDs stated on the right:

Advice for safe and trouble-free operation:

Ÿ

The specified maximum number of  LEDs for the converter 
must not be exceeded.

Ÿ

The LEDs must not be operated with a current higher than 
the specified rated current.

Ÿ

Individual sections of the Radar-LEDs system must only be 
connected  with  cables  approved  for  the  maximum  open-
circuit voltage of the converter used. 

Ÿ

The electric circuit must not be interrupted while the system 
is operational.

 

Ÿ

For the installation of the LED converters please refer to the 
respective installation instructions.

Converters

Converter type

C100/150

C100/300

C100/990

C100/300D

C100/990D

C100/990DALI

Max. no. of LEDs

20

42

150

42

150

150

Converter 

Power supply
230 V/50 Hz

+

+

WAGO
connector

WAGO
connector

Connection diagram for Radar Outdoor LEDs and converters

>>  Series connection  <<

Installation Instructions

Page 2/2

Hansen GmbH

Tel. +49 4843-2009 0    

§

    [email protected] 

 §

   www.hansen-led.de

Reviews: