9
10
1) Heat exchanger body
2) Thermostat mounting
3) Exhaust Flue
4) Wind shield
5) Gas burner
6) Gas connection
7) Sealing grommet
8) Gas Solenoid valve
9) Gas Injector
10) Spark Electrodes
Checking the spark & flame sense
1) Remove the upper heat plate by
loosening the securing 7mm nut.
2) Inspect the ceramic electrodes
for cracks
3) The distance between the spark
electrodes must be between 4-5mm.
4) The distance from the sense electrode
and the burner must be 4-5mm.
Summary of Contents for GE2
Page 1: ...MODEL GE2 DUAL GAS ELECTRIC WATER HEATER OWNER S MANUAL HANSEN...
Page 2: ......
Page 3: ......
Page 5: ......
Page 6: ...Plastic dust Travel cover...
Page 7: ...WARNING Supply pump pressure MUST NOT exceed 1 5 Bar Recommend pump Fiamma Aqua 8...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ...Black Spark Igniter Electronic Control Board 9 10...
Page 13: ...Manufactured by Hansen Water Heaters Pty Ltd www hansenproducts co za...