Hansa C5 O&M Manual - OM-025 Revision A 13/02/2020
© Hansa Chippers 2020
14
Adjust the anvil at this stage as the location
of knife edge will change after sharpening
or replacement.
The anvil is reversible. Normally the edge
will last for over 200 operating hours.
When the edge is dull, it can be reversed.
When both edges are worn, the anvil
should be replaced (contact Hansa for a
replacement).
The clearance between the knife and anvil
should be approx. 1 mm on the inside
closest to the bearing and 3 mm on the
outside closest to the edge of the rotor
(refer to diagram for more detail). Ensure
you are using the outer blade for
calibrating these distances.
8
Bearing
Edge of
rotor
Anvil
Cutting
rotor
Knife
1 mm
clearance
3 mm
clearance