Hans Grohe Tica 13251000 Instructions For Use/Assembly Instructions Download Page 4

4

English

Assembly 

(see page 7)

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 

injuries.

 

The product may only be used for bathing, hygienic and body cleaning 

purposes.

 

Children as well as adults with physical, mental and/or sensoric impairments 

must not use this product without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from using this product.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the 

applicable standards.

• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths!

Thermostatic mixer in conjunction with combination boil-

ers

• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different water 

pressures you must install a water limiter to the cold supply, (ordered separate-

ly,article number 97510000).

• Thermostatic mixer Shower: When using the Ecostat with combination boilers, 

the Ecostop safety set (95042000) has to be removed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Centre distance: 

150±12 mm 

Connections G 1/2: 

cold right - hot left 

Thermal disinfection: 

70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Safety Function 

(see page 8)

The desired maximum temperature for example max. 42º C can be pre-set thanks 

to the safety function.

Adjustment 

(see page 8)

After the installation, the output temperature of the thermostat must be checked. A 

correction is necessary if the temperature measured at the output differs from the 

temperature set on the thermostat.

ECOSTOP 

(see page 9)

Maintenance 

(see page 9)

• The check valves must be checked regularly according to EN 806-5 in 

accordance with national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary from time to 

time to turn the thermostat from total hot to total cold.

Dimensions 

(see page 12)

Flow diagram 

(see page 12)

  Shower outlet

  Tub outlet

Spare parts 

(see page 11)

Cleaning 

(see page 10)

Operation 

(see page 13)

Test certificate 

(see page 14)

Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump has been installed 

check to see if the pump is working).

- Regulator filter dirty

- Clean filter in front of the mixer and on the MTC-ther-

mo cartridge

- Shower filter seal dirty

- Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water 

pipe, or vice versa, when mixer is closed

- Backflow preventers dirty or leaking

- Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with 

temperature set

- Thermostat has not been adjusted

- Adjust thermostat

- Hot water temperature too low

- Increase hot water temperature to 42 ºC to 60 ºC

Temperature regulation not possible

- thermo cartridge calcified

- Exchange thermo cartridge

Shower drips continuously

- Dirt or sedimentation on valve seat, shut-off unit 

damaged

- Clean or exchange shut-off unit

Instantaneous heater didn't work with thermostat

- Filters are dirty

- Clean the filter / exchange filter

- check valve hasn't moved back

- Exchange check valves

- Flow limiter in handshower isn’t removed

- Remove flow limiter

- Ecostop safety set removed.

- Remove Ecostop safety set (95042000)

Summary of Contents for Tica 13251000

Page 1: ...ung Montageanleitung 2 FR Mode d emploi Instructions de montage 3 EN Instructions for use assembly instructions 4 NL Gebruiksaanwijzing Handleiding 5 DK Brugsanvisning Monteringsvejledning 6 Tica 1325...

Page 2: ...te H chsttemperatur von z B max 42 C voreinstellen Justierung siehe Seite 8 Nach erfolgter Montage muss die Auslauftemperatur des Thermostaten berpr ft werden Eine Korrektur ist erforderlich wenn die...

Page 3: ...42 C souhait e Etalonnage voir pages 8 Le montage termin contr ler la temp rature de l eau puis e au mitigeur thermostatique Un talonnage est n cessaire si la temp rature de l eau mitig e mesur e au...

Page 4: ...imum temperature for example max 42 C can be pre set thanks to the safety function Adjustment see page 8 After the installation the output temperature of the thermostat must be checked A correction is...

Page 5: ...tend ontworpen voor drinkwater Symboolbeschrijving Gebruik geen zuurhoudende silicone Safety Function zie blz 8 Dankzijd de Safety Function kan de gewenste maximale temperatuur van bijv max 42 C van t...

Page 6: ...s 8 Takket v re Safety varmtvands begr nsningen kan maksimaltemperaturen forudindstilles eksempel max 42 C Forindstilling se s 8 Efter monteringen skal termostatens udl bstemperatur kontrolleres S fr...

Page 7: ...7 X 36 mm X 36 X Silicone SW 30 mm 17 Nm max 39 mm max 5 mm 7 1 1 2 2 5 4 6 8 3b 3a 36 mm SW 24 mm...

Page 8: ...8 1 3 4 2 5 6 SW 3 mm SW 3 mm 2 Nm 1 2 1 2 1 4 6 5 SW 3 mm z B 42 C for example 42 C 2 3 SW 3 mm 2 Nm...

Page 9: ...9 1 2 4 3 5 6 SW 3 mm SW 3 mm 2 Nm z B 10 l min for example 10 l min 1 2 SW 30 mm 17 Nm 1 SW 30 mm 1 2 2 SW 10 mm 3 5 4 SW 10 mm 20 Nm Rot Rouge Red R d Rot Rouge Red R d...

Page 10: ...com cleaning recommendation www hansgrohe com cleaning recommendation DE Reinigungsempfehlung Garantie Kontakt FR Recommandation pour le nettoyage Garanties Contact EN Cleaning recommendation Warrant...

Page 11: ...000 SW 24 mm 98674000 98129000 14x2 94285000 96509000 92511000 M24x1 25 l min SW 22 mm 95041000 96467000 92836000 95433000 95042000 94149000 SW 17 mm 94140000 SW 24 mm 96429000 94285000 96467000 96157...

Page 12: ...9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15 18 21 24 27 30...

Page 13: ...40 C 40 C ffnen ouvert open bne ffnen ouvert open bne schlie en ferm close sluiten lukke schlie en ferm close sluiten lukke warm chaud hot varmt warm chaud hot varmt kalt froid cold koud koldt kalt fr...

Page 14: ...14 P IX DVGW SINTEF NF ETA 13251000 X 13253000 X...

Page 15: ...15...

Page 16: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 08 2021 9 07946 01...