2
English
Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt
leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and
guarantee claims.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 6)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 15)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 11)
Flow diagram
(see page 11)
Spare parts
(see page 14)
Special accessories
(order as an extra)
• extension 60 mm #93882000 (see page
14)
Cleaning
(see page 12)
Operation
(see page 7)
Hot and cold supplies are reversed (see page 8)
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Spout temperature does not
correspond with temperature set
- Hot and cold supplies are reversed - Install function block turned through
180° (see page 8)
Instantaneous heater didn’t work
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Talis S 72425009
Page 4: ...4 1 2 3 6 x M10x35 SW 8 mm 5 10452180 10 mm SW 8 mm 1 2 4 1 2 3 4...
Page 5: ...5 2 min 1 2 4 5 SW 22 mm SW 22 mm 2 Nm silicone 3 5 6 7 8...
Page 7: ...7 close open ffnen hot warm cold kalt 1 2 open ffnen...
Page 8: ...8 2 1 2 SW 8 mm 1 1 2 3 180 SW 6 mm 4 1 2...
Page 9: ...9 180 5 1 2 6 7 8 12 9 1 2 9 10...
Page 10: ...10 SW 6 mm 6 Nm 11 1 2 12 12 14 2 3 1 6x M10x35 SW 8 mm 2 1 3 13...
Page 13: ...13 1 min 1 2 max 10 min 20 mm 1 2 3 4 5 6...
Page 15: ...15 1 2 3...