4
Assembly see page 32
Test certificate
(see page 34)
Special accessories
seal (article number 98996000) order as
an extra
Spare parts
(see page 36)
Cleaning
see enclosed brochure.
Operation
(see page 35)
Due to the design of the Bidette fittings,
a small amount of water will leak at the
outlet of the fitting when the hand shower is
running.
Flow diagram
(see page 34)
Rate of flow mixer
Rate of flow handshower
Dimensions
(see page 34)
Maintenance non return valve
(see page 33)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 31.
Do not use silicone containing acetic acid!
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• The mixer can not used together with a continuous
flow water heater.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,25 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
anti-pollution function
English