4
Assembly see page 31
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
14146000 / 14466000 / 15447XXX / 31451000 /
31466000 / 31486000 / 31487000 / 31646000 /
31946000 / 32477000 / 71407000 / 71474000 /
72406000: Safety against backflow
The product is exclusively designed for drinking water!
English
Test certificate
(see page 48)
Spare parts
(see page 38)
Symbol description
Maintenance
(see page 36)
14146000 / 14466000 / 15447XXX /
31451000 / 31466000 / 31486000 /
31487000 / 31646000 / 31946000 /
32477000 / 71407000 / 71474000
/ 72406000: The safety device must be
checked regularly according to DIN EN
1717 in accordance with national or re-
gional regulations (at least once a year).
Fault
Cause
Remedy
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crossflow
-
Exchange cartridge
Diverter not operating
-
Residue
-
Clean converter / grease O-rings
-
Water pressure to low
-
Increase water pressure
-
Diverter defective
-
Exchange diverter
Do not use silicone containing acetic acid!
Adjustment
(see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions
(see page 34)
Flow diagram
(see page 35)
Rate of flow by 0,3 MPa:
Shower outlet
Tub outlet
Operation
(see page 41)
Cleaning
see enclosed brochure.