5
Fault
Cause
Remedy
Insufficient water
–
check valve hasn't moved back
–
Exchange check valves
–
filter insert shower dirty
–
Clean filter insert between shower
and hose
–
Shower filter seal dirty
–
Clean filter seal between shower
and hose
Mixer stiff
–
Cartridge defective, calcified
–
Exchange cartridge
Mixer dripping
–
Cartridge defective
–
Kartusche austauschen
Instantaneous heater didn’t work
–
check valve hasn't moved back
–
Exchange check valves
Hot water temperature too low
–
Hot water limiter incorrectly set
–
Set hot water limiter