background image

Assembly see page 4

English

Symbol description

Safety against backflow
The product is exclusively designed for drinking water!

Do not use silicone containing acetic acid!

Adjustment 

(see page 6)

To adjust the hot water limiter. Using a hot 
water limiter in combination with a continu-
ous flow water heater is not recommended.

Operation 

(see page 7)

Cleaning

see enclosed brochure.

Dimensions 

(see page 9)

Flow diagram 

(see page 9)

Spare parts 

(see page 10)

Maintenance 

(see page 8)

The check valves must be checked regularly 
according to DIN EN 1717 in accordance 
with national or regional regulations (at least 
once a year).

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be oberserved.

• The diverter (type HC) installed in the bath mixer is 

designed as an anti-retraction device. For this reason, 
the lower edge of the diverter must be at least 25 mm 
above the highest possible dirty water level.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 80°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

Fault

Cause

Remedy

Insufficient water

 

-

check valve hasn't moved back

 

-

Exchange check valves

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower 
and hose

Mixer stiff

 

-

Cartridge defective, calcified

 

-

Exchange cartridge

Mixer dripping

 

-

Cartridge defective

 

-

Exchange cartridge

Hot water temperature too low

 

-

Hot water limiter incorrectly set

 

-

Set hot water limiter

Instantaneous heater didn’t work

 

-

Flow limiter in handshower isn’t 
removed

 

-

Remove flow limiter

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower 
and hose

 

-

check valve hasn't moved back

 

-

Exchange check valves

2

Summary of Contents for Status2 14184009

Page 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Status 14186009 Status 14184009 ...

Page 2: ...e honoured The pipes and the fixture must be installed flushed and tested as per the applicable standards The plumbing codes applicable in the respective countries must be oberserved The diverter type HC installed in the bath mixer is designed as an anti retraction device For this reason the lower edge of the diverter must be at least 25 mm above the highest possible dirty water level Technical Da...

Page 3: ...nt Die Leitungen und die Armatur müssen nach den gülti gen Normen montiert gespült und geprüft werden Die in den Ländern jeweils gültigen Installationsrichtli nien sind einzuhalten Der im Wannenmischer eingesetzte Umsteller Typ HC ist als Einrichtung zur Absicherung gegen Rück saugung ausgeführt Daher muss sich die Unterkante des Umstellers min 25 mm über dem höchstmöglichen Schmutzwasserspiegel b...

Page 4: ...4 Silicone 1 2 min 34 mm 3a 4 5 3b max 39 mm max 5 mm 1 2 1 2 2 1 SW 24 mm ...

Page 5: ...5 6 7 SW 30 mm 20 Nm 8 9 10 2 min SW 22 mm SW 22 mm 2 Nm ...

Page 6: ...6 Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa ...

Page 7: ...7 close schließen open öffnen open öffnen hot warm cold kalt 1 2 ...

Page 8: ...8 SW 12 mm 3 2 1 2 1 2 2 1 1 3 3 SW 12 mm 1 1 2 2 3 ...

Page 9: ... bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 1B ...

Page 10: ...0 95008000 98193000 32x2 94140000 97220000 98163000 15x2 97209000 95140000 13914000 Status 14184009 92730000 Status 14186009 95332000 95140000 95008000 97209000 97406000 96338000 96429000 94140000 98193000 32x2 98129000 14x2 97220000 98163000 15x2 95673000 92730000 96044009 96157000 96467000 ...

Page 11: ...11 ...

Page 12: ...12 Hansgrohe Auestraße 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 06 2015 9 01376 61 ...

Reviews: