Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact
that a change of installation height will also change
the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The filter insert (97708000) must be used to ensure
the standard flow rate and to protect the hand
shower against incoming dirt by pipework. Do you
want a larger water flow rate, then you must use the
English
Symbol description
Safety Function
(see page 19)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Adjustment
(see page 18)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
filter packing (94246000) instead of the filter insert
(97708000). Incoming dirt leads to defects or/and
can damage parts of the hand shower; such caused
faults voids all liability and guarantee claims.
• The product is not designed to be used with steam
baths!
• If required, the bottom part of the pipe between the
fixture and the shower head can be shortened with a
fine-toothed saw.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
Do not use silicone containing acetic acid!
4
Summary of Contents for Raindance Showerpipe 27235000
Page 14: ...14 Montage Silicone 1 2 34 mm 3a 3b 98681000 max 39 mm max 5 mm 2 1 2 1...
Page 15: ...15 Montage 1230 4 5 6 2 1 SW 30 mm 17 Nm 7 8...
Page 16: ...16 Montage 2 1 9 13 11 10 50 mm 6 mm 2 3 SW 8 mm Silicone Silicone SW 8 mm 98681000...
Page 17: ...17 Montage Durchflussdiagramm 94246000 97708000 14 2 1 4 3 2 SW 3 mm 6 Nm 1 12 13...
Page 18: ...18 Justierung Justierung 1 4 2 3...
Page 20: ...20 41 1230 2370 1100 min 2420 60 65 460 465 1230 240 39 80 80 40 22 302 307 Ma e Ma e...
Page 22: ...22 1 Wartung 1 SW 3 mm 2 3 4 SW 30 mm 2 3 4 2 3 1 SW 10 mm...
Page 23: ...23 Wartung 7 4 3 2 SW 30 mm 17 Nm SW 3 mm 6 Nm SW 10 mm 20 Nm 6 5 5 1...
Page 24: ...24 Reinigung Reinigung 1 min 1 3 2 4...
Page 25: ...25 Reinigung SW 5 mm SW 5 mm 2 Nm 1 3 2 4...
Page 26: ...26 Reinigung 2 1 1 min 3 4 5...