Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 6)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance
(see page 14)
Dimensions
(see page 8)
Flow diagram
(see page 11)
free flow
Shower outlet
Tub outlet
Spare parts
(see page 16)
XX = Colors
00 = Chrome Plated
09 = Chrome Plated/Gold Plated
14 = Brushed Bronze
34 = Brushed Black Chrome
40 = White/Chrome Plated
67 = Matt Black
70 = Matt White
99 = Polished Gold-Optic
Special accessories
(see page 16)
order as an extra
• Extension Set 22 mm (when wall is not deep
enough)
• extension 25 mm #13595000
Cleaning
(see page 12)
Operation
(see page 7)
+
Fault
Cause
Remedy
Insufficient water (31365XX7 /
31965007 / 32565007 /
72605007 / 71605007 /
14637007 / 31456007 /
31665007 / 15665407 /
31685007 / 76615XX7)
- EcoSmart® dirty or leaking
- Clean or exchange EcoSmart®
(see page 14)
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Diverter not operating
- Residue
- Clean converter / grease O-rings
- Water pressure to low
- Increase water pressure
- Diverter defective
- Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
- Crossflow
- Exchange cartridge