Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter blue
marked copper pipe.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow:
max. 5 l/min
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Special accessories
(order as an
extra)
Spare parts
(see page 34)
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Dimensions
(see page 31)
seal #98996000 (see page 32)
Cleaning
(see enclosed brochure)
Symbol description
Operation
(see page 35)
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
• When the storage tank is being heated,
the spout will drip.
Do not use silicone containing acetic acid!
Table for the throttle hose lengths to be used
Highest possible water pressure at
user's site in Mpa
Device content
8, 10 and 15 liters
up to 5 liters
0,1 - 0,15
without throttle hose
Throttle hose shortened to 90 mm
0,2 - 0,3
Throttle hose shortened to 90 mm
Throttle hose unchanged
0,4 - 0,7
Throttle hose unchanged
Adjust flow volume at corner valve
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
Fault
Cause
Remedy
Insufficient water
-
Spray former calcified, dirty
-
Clean spray former, exchanging if
necessary
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping constantly with water
heater switched off
-
Cartridge defective
-
Exchange cartridge
4