background image

I N S T A L L A T I O N

EN

  Instructions for use / assembly instructions 

2

DE

  Gebrauchsanleitung / Montageanleitung 

4

Lesezeichen

English 

2

Deutsch 

4

Lesezeichen

Metropol Select 260

32572003

Metropol Select 110

32571003

Metropol Select 100

32570003

Summary of Contents for Metropol Select 100 32570003

Page 1: ...I N S T A L L A T I O N EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 4 Metropol Select 260 32572003 Metropol Select 110 32571003 Metropol Select 100 32570003 ...

Page 2: ... with EcoSmart flow limiter Operating pressure max 1 MPa Recommended operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 70 C Recommended hot water temp 65 C Thermal disinfection max 70 C 4 min The product is exclusively designed for drinking water Symbol description Do not use silicone containing acetic acid Adjustment see page 8 To adjust the hot w...

Page 3: ...pipe or vice versa when mixer is closed Backflow preventers dirty or leaking Clean backflow preventers exchange if necessary Instantaneous heater didn t work Filters are dirty Clean the filter exchange filter check valve hasn t moved back Exchange check valves Supply pressure inadequate Remove flow limiter Valve stiff leaking Select stop valve damaged soiled Exchange Select stop valve Temperature ...

Page 4: ...den Technische Daten Armatur serienmäßig mit EcoSmart Durch flussbegrenzer Betriebsdruck max 1 MPa Empfohlener Betriebsdruck 0 1 0 5 MPa Prüfdruck 1 6 MPa 1 MPa 10 bar 147 PSI Heißwassertemperatur max 70 C Empfohlene Heißwassertemperatur 65 C Thermische Desinfektion max 70 C 4 min Das Produkt ist ausschließlich für Trinkwasser konzipiert Symbolerklärung Kein essigsäurehaltiges Silikon verwenden Ju...

Page 5: ...sverhinderer verschmutzt defekt Rückflussverhinderer reinigen ggf austauschen Durchlauferhitzer schaltet nicht ein Schmutzfangsiebe verschmutzt Schmutzfangsiebe reinigen austauschen Rückflussverhinderer sitzt fest Rückflussverhinderer austauschen Versorgungsdruck nicht ausrei chend Durchflussbegrenzer entfernen Ventil schwergängig undicht Select Absperrventil beschädigt verschmutzt Select Absperrv...

Page 6: ...6 3 Nm 1 2 1 2 3 4 5 6 SW 10 mm SW 19 mm 4 Nm SW 24 mm 4 Nm 1 2 ...

Page 7: ...7 7 8 2 min ...

Page 8: ...8 2 3 1 4 5 60 C 10 C 6 35 C 39 C 43 C 47 C 57 C 60 C 0 3 MPa ...

Page 9: ...9 7 8 9 0 5 Nm max min ...

Page 10: ...03 Metropol Select 110 32571003 Metropol Select 260 32572003 2 0 Ø 32 max 40 175 390 48 48 159 172 84 G3 8 G3 8 G1 2 Ø 32 max 40 512 48 48 203 2 0 136 150 113 G3 8 G3 8 G1 2 Ø 32 max 40 370 48 48 206 219 345 255 2 0 G3 8 G3 8 G1 2 ...

Page 11: ...2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec close schließen open öffnen hot warm cold kalt EcoSmart 1 EcoSmart 2 ...

Page 12: ...12 SW 10 mm SW 19 mm 1 2 3 4 5 SW 19 mm 4 Nm SW 10 mm ...

Page 13: ...w hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleani...

Page 14: ...000 93048000 95661000 93070000 98866000 92528000 92526000 96456000 95291000 93395000 92996000 92527000 27x1 5 98398000 23x2 98422000 7x1 5 92529000 EcoSmart Metropol Select 100 32570003 Metropol Select 110 32571003 Metropol Select 260 32572003 92936000 32x1 5 ...

Page 15: ...15 ...

Page 16: ...straße 5 9 77761 Schiltach Deutschland info axor design com axor design com Hansgrohe Auestraße 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 03 2020 9 05223 32 ...

Reviews: