Assembly see page 31
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms.
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
anti-pollution function
•
•
English
Symbol description
Maintenance
(see page 36)
14466XXX / 14146XXX / 15447XXX /
31466000 / 31487000 / 31646000 /
31946000 / 32477000 / 31486XXX: The
safety device must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective, sedimentation
- Exchange cartridge
Diverter not operating
- Residue
- Clean converter / grease O-rings
- Water pressure to low
- Increase water pressure
- Diverter defective
- Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
- Crossflow
- Exchange cartridge
Do not use silicone containing acetic acid!
To adjust the hot water limiter on single lever
mixers, please see page 33. No adjustment
is necessary when using a continuous flow
water heater.
Dimensions
(see page 34)
Flow diagram
(see page 32)
Shower outlet
Tub outlet
Operation
(see page 35)
Test certificate
(see page 40)
Spare parts
(see page 38)
Cleaning
Cleaning recommendations, see enclosed
brochure.
4