3
English
Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During initial start-up and after servicing, air in the
fittings can cause noise. After switching the jet on
and off about 15 times, the noise will stop.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 11)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions
(see page 18)
Flow diagram
(see page 18)
Maintenance
(see page 14)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Cleaning
(see page 13)
Spare parts
(see page 16)
Special accessories
(order as an extra)
F12 extension #43333000 (see page 16 /
Operation
(see page 12)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when
opening the fitting via the lever.
• Use the lever to open the tap and set the desired
temperature. The water flow can be paused by
pressing the Select button on the face side of the
spout. When the tap is not used for a longer period
of time, f.e. when retiring at night or leaving the
house, it must be closed completely by means of the
lever.
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Low flow with Select valve after
valve replacement
- Improper Select valve installed
- Replace Select valve
(#98463000)
Select button stiff
- Select button soiled
- Clean Select button and grease
(#9820100) O-ring
Summary of Contents for Metris Select M71 320 2jet sBox 73816003
Page 5: ...5 150 45 105 75 75 45 105 24 x 15 7a ...
Page 6: ...6 24 x 15 7b 110 25 85 55 55 25 85 110 ...
Page 8: ...8 1 2 3 14 17 19 1 2 15 16 18 ...
Page 9: ...9 max 20 21a 21b 20 max 30 mm max 30 mm max 30 mm ...
Page 10: ...10 max 20 21c F12 43333000 21d max 20 2 min 23 1 2 24 1 2 22 ...
Page 12: ...12 öffnen open 1 2 schließen close warm hot kalt cold ...
Page 14: ...14 1 2 SW 10 mm SW 19 mm 4 Nm SW 10 mm SW 19 mm 1 2 1 2 3 ...
Page 15: ...15 2 1 2 5 1 2 1 3 4 95333000 95332000 ...
Page 17: ...17 1 2 max 100 mm F12 43333000 ...
Page 19: ...19 ...