4
English
Assembly
(see page 32)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 73827000: The mixer can not used together with a
continuous flow water heater.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 41)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance
(see page 43)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Cleaning
(see page 44)
Dimensions
(see page 46)
Flow diagram
(see page 47)
Spare parts
(see page 48)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories
(order as an extra)
• F12 extension #43333000 (see page 40)
• Adapter (G⅜ / G½)
#93395000 (see page 49)
Operation
(see page 42)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when
opening the fitting via the lever.
Test certificate
(see page 52)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose de-
fective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Low flow with Select valve after
valve replacement
- Improper Select valve installed
- Replace Select valve
(#98463000)
Summary of Contents for Metris Select M71 320 2jet 73806 Series
Page 32: ...32 SW 10 mm SW 19 mm 4 Nm 150 110 6a 6b max 35 mm 3 Nm max 60 mm 1a 2 1b 3 4 5...
Page 33: ...33 150 45 105 75 75 45 105 24 x 15 6a...
Page 34: ...34 24 x 15 110 25 85 55 55 25 85 110 6b...
Page 37: ...37 1 2 1 2 19 20 21 22 23 24...
Page 38: ...38 max 30 mm max 30 mm max 30 mm max 20 25 26a 26b...
Page 39: ...39 max 20 F12 43333000 max 20 27 26c 26d 28...
Page 40: ...40 2 min 1 Nm F12 43333000 max 100 mm 29 30 1 2...
Page 45: ...45 1 2 1 2...
Page 50: ...50...
Page 51: ...51...