![Hans Grohe Metris Select M71 220 2jet sBox 73805000 Instructions For Use/Assembly Instructions Download Page 4](http://html1.mh-extra.com/html/hans-grohe/metris-select-m71-220-2jet-sbox-73805000/metris-select-m71-220-2jet-sbox-73805000_instructions-for-use-assembly-instructions_2103006004.webp)
4
English
Assembly
(see page 31)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 35)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Maintenance
(see page 35)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
Dimensions
(see page 38)
Flow diagram
(see page 38)
Normal spray
Regular
Spare parts
(see page 39)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories
(order as an extra)
extension #43333000 (see page 39)
Cleaning
(see page 37)
Operation
(see page 36)
• Hansgrohe recommends not to use as drinking water the first half liter of water
drawn in the morning or after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when opening the fitting via the
lever.
Test certificate
(see page 40)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base
- connection hoses not completely screwed into basic
body
- Tighten connection hoses by hand
- O-ring at the connection hose defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Low flow with Select valve after valve replacement
- Improper Select valve installed
- Replace Select valve (#98463000) (see page 39)