4
Assembly
(see page 31)
Cleaning
(see page 38)
Flow diagram
(see page 34)
73841000:
without EcoSmart
®
with EcoSmart
®
73858000 / 73866000:
Rate of flow mixer
Rate of flow stop valve
Dimensions
(see page 34)
Operation
(see page 33)
Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
Adjustment
(see page 33)
To adjust the hot water limiter. Using a hot water limiter in combination
with a continuous flow water heater is not recommended.
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
73858000 / 73866000:
Only dishwashers and washing machines certified
with the DVGW emblem may be connected to the appliance connection valve
without an additional fuse. If no consumer is connected to the appliance
connection valve, it must be plugged.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
•
73841000:
If the instantaneous water heater causes problems or if you wish to
increase the water flow, the EcoSmart
®
(flow limiter) located behind the aerator
can be removed. (see page 36)
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Do not use silicone containing acetic acid!
Spare parts
(see page 36)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base
- connection hoses not completely screwed into basic
body
- Tighten connection hoses by hand
- O-ring at the connection hose defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter