4
English
Assembly
(see page 34)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• There must be an access door for maintenance.
• The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt
leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and
guarantee claims.
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,02 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Maintenance
(see page 47)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 37)
Flow diagram
(see page 42)
Tub outlet
Shower outlet
Spare parts
(see page 43)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
Cleaning
(see page 46)
Operation
(see page 36)
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- check valve hasn't moved back
- Exchange check valves
Instantaneous heater didn’t work
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- check valve hasn't moved back
- Exchange check valves