Hans Grohe Focus M42 180 2jet 71801007 Instructions For Use/Assembly Instructions Download Page 3

3

English

Assembly 

(see page 6)

 

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 8)

To adjust the hot water limiter. Using a hot water limiter 

in combination with a continuous flow water heater is 

not recommended.

Cleaning 

(see page 10)

Maintenance 

(see page 12)

The check valves must be checked regularly according 

to EN 806-5 in accordance with national or regional 

regulations (at least once a year).

Dimensions 

(see page 4)

Flow diagram 

(see page 4)

Spare parts 

(see page 13)

Operation 

(see page 9)

• Do not rotate the spout further than 360º or damage 

to the hose will result.

• Hansgrohe recommends not to use as drinking water 

the first half liter of water drawn in the morning or 

after a prolonged period of non-use.

Fault

Cause

Remedy

Mixer stiff

- Cartridge defective, calcified

- Exchange cartridge

Mixer dripping

- Cartridge defective

- Exchange cartridge

Water escaping at the threaded 

base

- connection hoses not completely 

screwed into basic body

- Tighten connection hoses by hand

- O-ring at the connection hose 

defective.

- Exchange O-ring

Hot water temperature too low

- Hot water limiter incorrectly set

- Set hot water limiter

Summary of Contents for Focus M42 180 2jet 71801007

Page 1: ...ZH 用户手册 组装说明 2 EN Instructions for use assembly instructions 3 Focus M42 220 2jet 71800007 Focus M42 180 2jet 71801007 ...

Page 2: ...47 PSI 热水温度 最大 70 C 推荐热水温度 65 C 热力消毒 最大 70 C 4 分钟 自动防止回流 该产品专为饮用水设计 符号说明 请勿使用含有乙酸的硅胶 调节 参见第页 8 热水温度调节 如果使用即热式喷头 则不建议 安装热水阀门 清洗 参见第页 10 保养 参见第页 12 单向阀必须在符合国家或当地的法律的情况下按 照EN 806 5定期检查 至少一年一次 大小 参见第页 4 流量示意图 参见第页 4 备用零件 参见第页 13 操作 参见第页 9 水嘴旋转不可超过360º 否则会导致软管受 损 汉斯格雅建议 清晨或在水流长时间停滞后 前半升水不作饮用水使用 问题 原因 补救 龙头不灵活 阀芯损坏 结垢 更换阀芯 龙头滴水 阀芯损坏 更换阀芯 水从螺纹底座中流出 连接软管没有完全旋入基体 用手拧紧连接软管 连接软管的O形环损坏 更换O形环 热水温度过低 温度限制器设置错误 ...

Page 3: ...containing acetic acid Adjustment see page 8 To adjust the hot water limiter Using a hot water limiter in combination with a continuous flow water heater is not recommended Cleaning see page 10 Maintenance see page 12 The check valves must be checked regularly according to EN 806 5 in accordance with national or regional regulations at least once a year Dimensions see page 4 Flow diagram see page ...

Page 4: ... Ø 550 52 Ø max 60 182 97 G1 2 1 2 360 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec Focus M42 220 2jet 71800007 ...

Page 5: ...0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec c a 5 0 0 125 148 85 15 207 224 28 Ø 68 165 52 Ø 183 364 182 97 34 Ø 550 max 60 G1 2 Focus M42 180 2jet 71801007 ...

Page 6: ...6 SW 10 mm SW 24 mm 4 Nm 3 Nm 1 2 3b 1 2 max 35 mm max 60 mm 3b 1 2 3a 4 5 6 ...

Page 7: ...7 80 1 CLICK 3 4 2 2 min 1 Nm 7 8 9 10 11 12 ...

Page 8: ...0 3 MPa 60 C 10 C 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm 8 ...

Page 9: ...9 开 open 热 hot 冷 cold 关 close ...

Page 10: ...10 Hansgrohe Hansgrohe www hansgrohe int com guarantee QuickClean QuickClean 10 QUICK CLEAN ...

Page 11: ... products as the atomised spray could enter openings and gaps in the Hansgrohe products and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue The use of steam cleaners is not permitted The high temperatures can damage the products Important Residues of toiletries such as liquid soaps shampoos and shower gels hair dyes perfumes aftershave and nail varnish c...

Page 12: ...12 1 1 2 2 ...

Page 13: ...500000 400g 95507000 1500 mm 92730000 93340000 71800007 93341000 71801007 95008000 98156000 36x2 98193000 32x2 98127000 11x2 98422000 7x1 5 97523000 97827000 8x1 75 98365000 98211000 21x2 5 93343000 95910000 94074000 93342000 98173000 22x1 5 97548000 Focus M42 220 2jet 71800007 Focus M42 180 2jet 71801007 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...Hansgrohe Auestraße 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 06 2020 9 06179 52 ...

Reviews: