4
English
Assembly
(see page 32)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 73895000: The mixer can not used together with a
continuous flow water heater.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 38)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance
(see page 40)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Dimensions
(see page 39)
Flow diagram
(see page 40)
Spare parts
(see page 43)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories
(order as an extra)
extension #43333000 (see page 37)
Adapter (G⅜ / G½)
#93395000 (see page 44)
Cleaning
(see page 41)
Operation
(see page 45)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate
(see page 48)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Focus M41 240 1jet sBox 73880 Series
Page 32: ...32 SW 10 mm SW 19 mm 4 Nm max 45 mm max 70 mm 3 Nm 1a 2 3 4 5 1b 150 110 110 150...
Page 34: ...34 12 1 2 13 14 15 16 max 30 mm max 30 mm max 30 mm...
Page 35: ...35 17a 17b max 20 17c max 20...
Page 36: ...36 max 20 17d F12 43333000 20 21 1 Nm 2 min 18 19...
Page 37: ...37 1 F12 43333000 2 max 100 mm...
Page 42: ...42 2 1 2 1...
Page 46: ...46...